Regency C33-NG3 Manuel D’Utilisation

Page de 28
Regency
®
 CLASSIC C33-3 Freestanding Gas Stove
7
Diagram 4
9)  Lift the fan assembly in through the pedestal 
and up through the cut out as shown in 
diagrams 3 and 4.
10) Put the insulation gasket on the back of 
the fan. Line up the keyhole slots with the 
matching screws and pull back slightly to 
lock into place. While holding fan assembly 
in place, tighten screws.
Diagram 3
Diagram 2
OPTIONAL FAN 
INSTALLATION
Important: Disconnect the power 
supply before installation or serv-
icing.
For pedestal unit: To install the fan in an in-
stalled stove-access from front through the 
pedestal by following the directions below. 
If the stove is not installed - access through 
rear and follow steps 4 to 17.
Diagram 1
INSTALLATION
CLEARANCES TO 
COMBUSTIBLES
The clearances listed below are MINIMUM 
distances.  Measure the clearance to both the 
appliance and the chimney connector. The far-
thest distance is correct if the two clearances do 
not coincide. For example, if the appliance is set 
as indicated in one of the diagrams but the back 
wall is too close, move the stove until the correct 
clearance to the back wall is obtained.  
This unit can be installed on a solid combustible 
surface like a wood fl oor. This unit can also be 
installed directly on carpeting or vinyl when the 
bottom pedestal cover plate (provided with the 
unit) is installed.
This appliance may be installed only with the 
clearances as shown in the situations pictured.  
Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances. Use the minimum clearances 
shown in the diagrams. Alcove installations are 
approved, as long as side wall clearances are 
maintained.
C33-3 Clearances to Combustibles
A  Side Wall to Unit 
10" / 250 mm
B  Back Wall to Unit 
6" / 150 mm
E  Side Wall to Unit 
1.5" / 38 mm
 
 C33-3 Reference Dimensions
  
to 
Flue 
Centerline
C  Back Wall 
11-1/2"/ 292 mm
D  Side Wall 
22" / 559 mm
F  Side Wall 
13" / 330 mm
Minimum ceiling height is 36" / 914 mm from 
This includes:
1)
  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.
2)  If required, adjusting the primary air to 
ensure that the fl ame does not carbon. 
First allow the unit to burn for 15-20 min. 
to stabilize.
3)  Check for proper draft.
CAUTION: Any alteration to the product that 
causes sooting or carboning that results 
in damage is not the responsibility of the 
manufacturer.
For leg unit: remove 7 screws,  remove bottom 
access panel and install fan assembly and 
follow steps 4 to 17.
1)  Open pedestal door and remove door cover 
plate by removing 4 screws. See diagram 
1.
2)  Remove valve cover plate by removing 2 
screws.
3)  Remove wire from piezo ignitor.
4)  Screw the four 8-32 x 3/4 screws provided 
into the nutserts as shown in diagram 3. Do 
not tighten screws.
5)  Push all the fan wires through the hole on 
the fan assembly. See diagram 2
.
6)  Put power cord (shown in diagram 3) through 
the hole and pull through to front of unit for 
easier installation of ground wire. 
7)  Place fan assembly partially in door cover 
plate hole. See diagram 2.
8)  Attach the 2 ground wires (green) to the 
ground lug as per diagram 2.
Note:Ground lug is located on the bottom of the 
fan assembly. See diagram 2.