Regency F39-NG Manuel D’Utilisation

Page de 31
Regency
®
 F39 Room Sealed Freestanding Gas Stove
25
Mitred Glass Replacement
Removing Glass
1)  Remove the door from the unit and place 
on a soft surface to prevent scratching.
2)  Pull out the door gasket.
3)  Remove the 24 nuts holding the glass 
retainers in place. Do not remove the nuts 
underneath the retainers.
4)  Remove the door catch plate.
5)  Remove glass retainers on sides fi rst (3 each 
side) then remove two center retainers.
Note:  Center glass retainers are glued to 
center glass.
6)  Remove glass from extrusions. When re-
moving center glass, leave white insulation 
in place.
Installing Glass
2)  Place glass assembly into door frame.
3)  Install retainers by placing 1 drop of glue 
where previously glued and put in place.
4)  Install side retainers.
5)  Install door catch plate.
6)  Install the 24 nuts loosely, do not tighten 
yet.
1)  Install both center 
and side glass 
onto extrusions 
as per diagram.
Panel Glass Door Assembly
Wraparound Assembly Door 
(same glass retainers as the 
Panel Assembly)
Note:  Wearing gloves will protect your hands 
while handling glass.
Panel Glass Replacement
1)  Remove the door from the unit and place on 
a soft surface to prevent scratching.
2)  Pull out the door gasket.
3)  Remove the nuts holding the glass retainers 
in place.
4)  Remove the glass retainers (sides, top and 
bottom) and the door catch plate.
5)  Replace the glass. The glass must have 
gasketing around it.
6)  Reverse the previous steps, replace the 
retainers and fasten with the nuts but do 
not overtighten, as this can break the glass. 
Note: the  door catch plate fi ts on top of the 
left side retainer.
7)  Put gasket glue on the retainers, but do not 
put glue on the screws. Replace the door 
gasket, the two ends butt tight together on 
the bottom edge of the door.
8)  Replace door on the stove and check the 
seal.
LOG REPLACEMENT
The unit should never be used with broken logs. 
Turn off the gas valve and allow the unit to cool 
before opening door to carefully remove the 
logs. The pilot light generates enough heat to 
burn someone. If for any reason a log should 
need replacement, you must use the proper 
replacement log. The position of these logs 
must be as shown in the diagram under Log 
Installation.  
Note:  Improper positioning of logs may 
create carbon build-up and will alter 
the unit’s performance which is not 
covered under warranty.
DOOR GASKET 
 
If the door gasket requires replacement use 7/8" 
diameter oval door gasket (Part # 650-920). 
LATCH ADJUSTMENT
The door latch may require adjustment as the 
door gasket material compresses after a few fi res 
and after glass replacement. Turn the adjustable 
catch to tighten or loosen the latch.
GLASS REPLACEMENT
Your Regency
®
 stove is supplied with high tem-
perature, 5 mm Neoceram ceramic glass that 
will withstand the highest heat that your unit will 
produce.  In the efl ue that you break your glass 
by impact, purchase your replacement door from 
an authorized Regency
®
 dealer only, and follow 
our step-by-step instructions for replacement. 
The glass is not sold separately, as it must be 
properly sealed in the door frame.
 
Replacement Part #
940-325/P F39 
Wraparound 
Glass
940-322/P 
F39 Panel Center Glass
940-323/P 
F39 Panel Side Glass
WARNING: Do not operate appliance 
with glass panels removed, cracked 
or broken. Replacement of the glass 
should be done by a licensed or 
qualifi ed service person.
MAINTENANCE