Regency F37-LPG Manuel D’Utilisation

Page de 28
F37 Regency
®
 Rear Flued Room Sealed Freestanding Gas Heater
11
Diagram 5
Diagram 4
 
 
Below Grade Snorkel Installation
 
 
If the Snorkel Termination must be installed 
below grade, i.e. basement application, 
proper drainage must be provided to prevent 
water from entering the Snorkel Termination. 
Refer to Dura-Vent Installation instructions 
for details.. Do not attempt to enclose the 
Snorkel within the wall, or any other type 
of enclosure.
4)  Install wall penetration heat shield in the center 
of the 9-1/2" round hole and attach with wood 
screws. The four wood screws provided should 
be replaced with appropriate fasteners for 
stucco, brick, concrete, or other types of sidings. 
Diagram 3.
NOTE: For  Snorkel terminations  in ABOVE 
 
grade installations, follow national or 
local code requirements.
Diagram 3
5)  If installing termination on a siding covered 
wall, a vinyl siding standoff or furring strips 
must be used to ensure that the termination is 
not recessed into the siding.  Diagram. 3.
6)  Take the Riser Vent terminal and separate the 
Backing Plate from the Riser Vent Front by 
removing 8 screws as shown in diagram 4.
7)  Install the Backing Plate into the wall 
penetration heat shield and attach using 
4 screws. Diagram 4.
8)  Connect all pipe sections to unit and 
install into wall:
 a)  Measure pipe length required and 
cut to length. Hint: use the cut end 
of the 6-5/8" dia. outer pipe at the 
fl ue terminal end.
 b)  Push the pipe sections completely 
together, the minimum pipe overlap 
is 1-1/4".  Secure all outer pipe joints 
by using at least two screws. Locate 
the screws at the bottom of the pipe 
so that the screw heads are hidden 
on the fi nal installation. Apply seal-
ant "Mill-Pac" to inner pipe and high 
temp silicone sealant or "Mill-Pac" 
to outer pipe on every joint.
 
Hint: Apply sealant to female end.
 c)  Before connecting the fl ue pipe to 
the  fl ue termination, slide the black 
decorative wall thimble cover over 
the fl ue pipe, then slide the Wall 
Penetration Heat Shield (Part # 
946-202) over the fl ue pipe. Diagram 
3.
 d)  Slide the appliance and fl ue assem-
bly towards the wall carefully insert-
ing the fl ue pipe into the riser vent 
terminal assembly. It is important 
that the fl ue pipe extends into the 
Riser Vent Backing Plate a suffi cient 
distance so as to result in a minimum 
pipe overlap of 1-1/4 inches. Secure 
the connection between the fl ue pipe 
and the fl ue cap by attaching the two 
sheet metal strips extending from 
the Riser Vent Backing Plate into the 
outer wall of the fl ue pipe. Use two 
aluminum screws provided to con-
nect the strips to the pipe section. 
Bend any remaining portion of the 
sheet metal strip back towards the 
fl ue cap and cut off any excess, it will 
be concealed by the decorative wall 
thimble cover. See diagram 5.
8)  Slide the decorative wall thimble up to the 
wall surface being careful not to scratch the 
paint.  See diagram 5.
9)  Back outside: Apply sealant to the 4" inner 
fl ue and slide the Riser Vent Front into the 
Backing Plate and fasten with 8 screws.
 IMPORTANT:
 
When connecting the pipe to the Riser 
Vent, apply Mill-Pac to the inner pipe on 
the Riser Vent Terminal, around the bead. 
Ensure that the fl ue pipe is pushed past 
the bead for a secure fi t. 
INSTALLATION
10) Seal around the outer edge of the Riser 
Vent Backing Plate.