Quadra-Fire CB1200-B Manuel D’Utilisation

Page de 48
Page  2
7014-082D
September 1, 2008
CB 1200 Pellet Stove 
and Welcome to the Quadra-Fire Family
!
Hearth & Home Technologies welcomes you to our tradi-
tion of excellence!  In choosing a Quadra-Fire appliance, 
you have our assurance of commitment to quality, durabil-
ity, and performance.
This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum operation 
of our stoves, inserts and fireplaces.  And yet we are old-
fashioned  when  it  comes  to  craftsmanship.    Each  unit  is 
meticulously fabricated and surfaces are hand-finished for 
lasting beauty and enjoyment.  Our pledge to quality is com-
pleted as each model undergoes a quality control inspec-
tion.    From design, to fabrication, to shipping: 
We wish you and your family many years of enjoyment in 
the warmth and comfort of your hearth appliance.  Thank 
you for choosing Quadra-Fire.
SAMPLE SERIAL NUMBER / SAFETY LABEL LOCATION:  
Behind left side curtain on outside of hopper wall.
SA
MP
LE
 
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / 
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:  
U.S. ENVIRONMENTAL PROTECTION AGENCY  This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"].
7014-079
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE 
Made in China/Fait Aux Chine 
1445 Highway North 
Colville, WA  99114 
www.quadrafire.com 
Back Wall to stove / Mur Arrière du poêle
2"/51mm
Side Wall to Cast Top / Mur De Côté du haut 
6"/152mm
CORNER INSTALLATION / NSTALLATION DU COIN :
Side Wall / Mur De Côté 
2"/51mm
VERTICAL ADAPTER KIT INSTALLATION: 
UN ASSEMBLAGE POUR ADAPTEUR  POUR INSTALLATION VERTICALE:
D
Back Wall to Flue Pipe / Mur Arrière tuyau rigide
3"/76
mm
Side Wall to Cast Top / Mur De Côté du haut 
6"/152mm
CORNER INSTALLATION WITH VERTICAL ADAPTER KIT: 
INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL:
Side Wall / Mur De Côté 
2"/51mm
ALCOVE INSTALLATION /
INSTALLATION DE L' ALCÔVE:
Max. Alcove Depth: / La profondeur maximum de l'alcôve
36"/914mm
Back Wall to stove / Mur Arrière du poêle
2"/51mm
Side Wall to Cast Top / Mur De Côté du haut 
6"/152mm
Unit corner to diagonal wall / 
2" (51mm) 
Top of Unit to Combustibles / Du poêle du haut combustibles                           12.5"/318mm 
 
Alcove vertical installation / Installation verticale de l'alcôve
D
Back Wall to Flue Pipe / Mur Arrière tuyau rigide
3"/76
mm
Floor  protector  must  be  noncombustible  material,  extending  beneath  heater  and  to  the 
front/sides/rear as indicated.  Measure front distance (I) from the surface of the glass door.
G =  2"/51mm 
H* = 2"/51mm 
 I  =  6"/152mm 
FLOOR PROTECTION / PROTECTION DU SOL 
Note  1:  In  residential  installations,  when  using  Parts  811-0580,  (3"  -  3"  Top  Vent  Adapter)  and 
812-2690 (3" - 6" Top Vent Adapter Collar) 24 gauge 6" single wall flue connector may be used. 
Note 1: Dans les installations résidentielles, lorsque les pièces 811-0580, (dessus de l'adapteur de
ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), un tuyau connecteur de 6" 
pour mur simple de calibre 24 peut être utilisé. 
Note 2: In manufactured home installation, when using Part 811-0580, (3" - 3" Top Vent Adapter) and 
812-2690 (3' - 6" Top Vent Adapter Collar), use listed double wall flue connector.  An Outside Air Kit 
(Part 811-0560 rear or 811-0570 floor), must be used with manufactured home installation. 
Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces 811-0580 (dessus de
l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), utilisez un 
tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0560 arrière
au 811-0570 la plancer), doit être utilisé pour l'installation dans les maisons préfabriquées. 
*Non-combustible floor protection must extend beneath the flue pipe when installed with 
horizontal  venting  or  under  the  Top  Vent  Adapter  with  vertical  installation.  
RECOMMENDED IN USA;  REQUIRED IN CANADA 
Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les 
schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée. 
*Un  protecteur  incombustible  de  plancher  doit  s'étendre  sous  le  conduit  de  cheminée  pour  une 
installation  de  ventilation  horizontale  ou  sous  un  adapteur  de  ventilation  de  dessus  pour  une 
installation verticale. ÉTATS-UNIS - RECOMMANDÉ;  CANADA - REQUIRENT 
D
B
C
C
E
E
B
H*
G
G
I
B
C
C
F
D
 2008    2009    2010   JAN   FEB   MAR   APR    MAY    JUNE   JULY   AUG   SEPT  OCT    NOV  DEC
Listed Solid Fuel Room Heater/Pellet Type Insert.  Also suitable for Mobile Home Installation.  This appliance has 
been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909. 
Tested to: ASTM E1509-95, ULC/ORD-C-1482-M1990, ULC S627-M93 Room Heating Pellet Burning Type, 
APFI, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL.
Input Rating:  40,000 Btu's/hr
Electrical Rating: 115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS.
Route power cord away from unit. Do not route cord under or in front of appliance.
DANGER:  Risk of electrical shock.  Disconnect power supply before servicing.  Replace glass only with 5mm 
ceramic  available  from  your  dealer.    To  start,  set  thermostat  above  room  temperature,  the  stove  will  light 
automatically.  To shutdown, set thermostat to below room temperature.  For further instruction refer to owner's 
manual.Keep viewing and ash removal doors tightly closed during operation.
Testé à: ASTM E1509-95, ULC/ORD-C 1482-M1990, ULC S627-M93 Room Heating.  Pellet Burning Type, APFI, (UM) 
84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS.
Puissance de Rendement: 40,000 Btu's/hr
Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps, 
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique.  Déconnectez le fil électrique de la prise de contact avant le service.
Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.
Pour  allumer,  monter  la  température  du  thermostat  au  dessus  de  la  température  de  la  pièce,  le  poêle  s'allumera 
automatiquement.  Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce.  Pour des 
instructions  supplémentaires,  référez  vous  au  manuel  du  propriétaire.    Gardez  la  porte  d'ouverture  et  la  porte  des  cendres 
fermées hermétiquement durant l'opération.
Appareil de chauffage inséré de combustible solide/de type de boulettes.  Accepté dans l'installation dans les maisons mobiles.  Cet 
appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
R
Report / Rapport
061-S-21-4
CB 1200 Pellet Stove 
SERIAL NO. / NUMÉRO DU
CAUTION:
HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE 
SKIN BURNS.  SEE NAMEPLATE AND INSTRUCTIONS.  Operate this unit with fuel hopper lid closed.  Failure to do so may result in emissions 
products' combustion from the hopper under certain conditions.  Maintain hopper seal in good condition.  Do no over fill the hopper. 
ATTENTION: 
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE 
CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU.  VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.  Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne 
pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine. 
007C
O-T L
Tested and 
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
Testing Lab & 
Report Number
Serial Number
Model
Mfg Date