CB 1200 Pellet Stove 
*L Exception for Horizontal Installations:
USA INSTALLATIONS
: A non-combustible floor protec-
tion  is  recommended  extending  beneath  the  flue  pipe 
when  installed  with  horizontal  venting  or  under  the  top 
vent adapter with vertical installation.
CANADA  INSTALLATIONS:    A  non-combustible  floor 
protection  extending  beneath  the  flue  pipe  is 
required 
with horizontal venting or under the top vent adapter with 
vertical installation.
Must extend 2 inches (51mm) beyond each
side of pipe  (shaded area)
C. Hearth Pad Requirements (UL and ULC)
L*
K
K
M
Use a non-combustible floor protector, extending beneath 
appliance  and  to  the  front,  sides  and  rear  as  indicated.  
Measure front distance “M” from the surface of the glass 
door.
Hearth Pad Requirements
Inches Millimeters
K
Sides
2
51
L*
Back
2
51
M
Front
6
152
Alcove Installation
Inches Millimeters
Minimum Alcove Height
44
1117
Minimum Alcove Width
40-1/2
1029
Maximum Alcove Depth
6
915
Minimum Alcove Side Wall
6
152
Top of Unit to Combustibles
12-1/2
18
Figure 9.1
Figure 9.2