England's Stove Works 10-CDV Manuel D’Utilisation

Page de 31
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1. 
If 3” flue pipe exceeds 15’ in length, increase to 4” flue pipe for remaining flue connections. 
2. 
Total flue length should not exceed 35’. 
3. 
Horizontal run not to exceed 4’. 
4. 
Floor protector required:  Min. size 36” x 36”. 
5. 
If the total run of outside air connection exceeds 6’, if more than 2 elbows are used, or if a 
basement install, use 3” metal pipe (and coupler) instead. 
6. 
Outside Air is mandatory for proper safe operation.
 
Freestanding Corn/Pellet Installation 
Caution: Follow the pipe manufacturer’s installation instructions and directions for 
passing through combustible walls and ceilings. Check local codes in your area.
Our Part AC-33000 
is acceptable for 
through-the-wall 
installation. 
(We recommend 4” 
for 2500+ ft. 
installations.) 
Must have 
minimum 3” 
adapter before tee 
for longer run.   
For shorter run 
(such as Masonry 
Connection below), 
tee alone is 
acceptable. 
Illustration 1
 
Basement Installation 
should be performed by 
professional installer.  Use 
3” metal pipe and coupler 
for Outside Combustion 
Air.  Minimum 3’ clearance 
from ground to the Pellet 
Vent Exhaust Pipe.
 
FLOOR AND WALL PROTECTION 
Floor Protection 
If your floor is constructed of a non-combustible material such as brick or concrete, there is no need for 
floor protection. If the floor is constructed of a combustible material such as hardwood, linoleum, or carpet, then 
you will be required to use floor protection between the unit and the combustible. The protection should be U.L. 
approved or equal, and should be large enough to provide a minimum of six inches (6”) behind and on both 
sides of the stove. The clearance in front of the stove should be at least six inches (6”). This freestanding pellet 
unit will need a minimum 36” x 36” floor protector. 
 
Wall Protection 
From the rear of this stove only three inches (3”) of clearance is required to paneling, wallpaper or drywall.  
The same clearance (3”) is required to a corner wall.   Six inches (6”) would be required to a sidewall.  Alcove 
clearances:  Six inches (6”) is required to an alcove sidewall; three inches (3”) is required to an alcove 
backwall, and seventeen inches (17”) is required to an alcove ceiling.  The corn vent pipe would require the 
standard three inches (3”) clearance, or as recommended by the manufacturer. Normally additional wall 
protection is not required with this type unit.  
 