Tyco Electronics MM23016 Manuel D’Utilisation

Page de 102
MM23016, Rev. C 
33 
Table 7-6: Scan Modes 
SCAN 
MODE 
EXPLANATION 
No Scan 
Eliminates distractions
Full communications (transmit and receive) on selected talk group. 
No calls received from other talk groups. 
Normal  
(Default) 
The user can scan all talk groups in the active profile that are not locked out as long as 
there is demand on the site. 
Priority (P1 and P2) groups are user selectable. 
Receive calls from more than one talk group, if available from the current site. 
Allows dragging of the selected talk group, P1, P2, and default emergency talk groups to 
the site on which the radio is registered. (If other calls are available at the site, they also 
can be heard but they will not be actively dragged.) 
The default emergency talk group, as well as any emergency-enabled talk groups, is only 
dragged if it is in emergency mode. 
Fixed 
Functions the same as Normal Scan Mode, except the priority groups are fixed to the 
selected profile’s pre-defined P1 and P2 groups (configured via the UAS). In this mode, 
P1 and P2 groups CANNOT be locked out. 
7.25.1 Checking or Changing Active Scan Mode 
The currently active scan mode does not appear in the dwell display. To check it, access “ScnModeMenu” 
and observe it in the top line of the display. To change the active scan mode: 
1.  Use 
 to scroll through the menus until “ScnModeMenu” appears in the display. 
2.  Use 
 to scroll through the scan options until the desired mode appears. See Table 7-6.