Enviro EF-119 Manuel D’Utilisation

Page de 39
Operating Instructions
A
UTOMATIC
 S
AFETY
 F
EATURES
:
Your pellet Stove has the following safety features:
A. The  stove  will  shut  off  when  the  fire  goes  out  and  the  exhaust  temperature  drops  below  120°F 
(49°C).
B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F 
(93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature 
cools.  If this happens, call your local dealer to reset the 200°F (93°C) high limit switch. ALSO FIND 
THE REASONS WHY THE UNIT OVERHEATED.
C. The unit has a convection fan control over-ride.  This function causes the convection fan to reach its full 
speed when the temperature at the back of the firebox reaches 160°F (71°C).  This is a normal safety 
feature of your unit.  To compensate for the fan cycling action that may occur, turn up the blower 
control proportionately to the heat output.
D. If the power goes out, the unit will stop running.  When the power comes back on, the stove will not 
restart unless the exhaust temperature is still above 120°F (49 °C).
S
LIDER
/D
AMPER
 S
ETTING
:
This is used to regulate the airflow through the pellet stove.
A Qualified Service Technician or Installer should mark the slider rod in the current settings.
SPECIAL NOTES:
���� ����
������
�������� ���
����� ���� ���
������ ����� ��
��������� �����
�� ��������
Figure 1: Slider / damper 
positions.
Pellet quality is a major factor in how the Pellet stove will operate. If the pellets 
have a high moisture content or ash content the fire will be less efficient and 
has a higher possibility of the fire building up and creating clinkers (hard ash 
build-up).
If  the  fire  should happen to  go  out  and the  Dial-A-Fire  has  been  set  on the 
lowest setting, the Slider Damper should be pushed in slightly, decreasing the 
air in the firebox or the Dial-A-Fire can be turned up slightly.
If, after long periods of burning, the fire builds up and overflows the burn pot 
or there is a build up of clinkers, this would be a sign that the pellet quality is 
poor, this requires more primary air, the slider damper must be pulled out to 
compensate. Pulling the slider damper out gives the fire more air.
The easiest way to make sure that an efficient flame is achieved is to understand 
the characteristics of the fire.
•  A tall, lazy flame with dark orange tips, requires more air – Open slider (pull 
out) slightly.
•  A short, brisk flame, like a blowtorch, has too much air – Close slider (push 
in) slightly.
•  If the flame is in the middle of these two characteristics with a bright 
yellow/orange, active flame with no black tips then the air is set for proper 
operation.
Taking a reading of vacuum pressure inside the firebox with a magnehelic gauge 
can be used to set the slider for best combustion. The best settings are a 
reading of 0.12 to 0.13 inches of water column (30 Pa) on the high fire 
setting.  Some fuels may require higher or lower settings. The reading 
can be taken from the 1⁄8” (3 mm) hole located on the front of the unit below 
the door and behind the magnetic ash lip.
6