Enviro 50-1221 Manuel D’Utilisation

Page de 31
4
Introduction
ELECTRICAL:  The  use  of  a  surge  protected  power  bar  is  recommended.  The  unit  must  be 
grounded.  The  grounded  electrical  cord  should  be  connected  to  a  standard  110-120  volts,,  nominal 
average 2.0 Amps (4.1  Amps peak), 60 hertz electrical outlet and also must be accessible. If this power 
cord should become damaged, a replacement power cord must be purchased from a qualified ENVIRO 
dealer. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot 
surfaces or sharp edges. This unit’s maximum power requirement is 184 watts (322 watts peak).
GLASS: Do not abuse the glass by striking or slamming the door.  Do not attempt to operate the stove 
with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO 
dealer.  Do not attempt to open the door and clean the glass while the unit is in operation or if glass is 
hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, 
or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the 
glass.
FLAMMABLE  LIQUIDS:  Never  use  gasoline,  gasoline-type  lantern  fuel,  kerosene,  charcoal  lighter 
fluid, or similar liquids to start or “freshen up” a fire in the heater.  Keep all such liquids well away from 
the heater while it is in use.
SMOKE  DETECTOR:  Smoke  detectors  should  be  installed  and  maintained  in  the  structure  when 
installing and operating a pellet burning appliance.
OPERATION: The ash pan and door must be closed securely for proper and safe operation of the pellet 
stove. Also ensure all gaskets on the door are checked and replaced when necessary.  
INSTALLATION: Be sure to maintain the structural integrity of your home when passing a vent through 
walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any 
displacement.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
FRESH AIR:  Outside fresh air must be connected to all units installed in Mobile and “Air Tight Homes” 
(R2000) or where required by local codes. Consider all large air moving devices when installing your unit 
and provide room air accordingly. Outside fresh air connection is optional in all other installations. Limited 
air for combustion may result in poor performance, smoking and other side effects of poor combustion.
If you have any questions with regards to your stove or the above-mentioned information, please feel 
free to contact your local dealer for further clarification and comments.
SINCE  SHERWOOD  INDUSTRIES  LTD.  HAS  NO  CONTROL  OVER  THE  INSTALLATION  OF 
YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED 
FOR  THE  INSTALLATION  OR  MAINTENANCE  OF  YOUR  STOVE.  THEREFORE,  SHERWOOD 
INDUSTRIES LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE