Sylvania 49671 Fascicule

Page de 2
63
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
Starting Method: Programmed
Start
Circuit Type: Series
Lamp Frequency: > 40 KHz
Lamp CCF: Less than 1.7
Starting Temp: 50°F minimum
Input Frequency: 60 Hz 
Low THD: < 10%
Power Factor: > 98%
Voltage Range: +/–10% of 
Rated Input 
UL Listed Class P, Type 1 Outdoor
CSA Certified
70°C Max Case Temperature
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
ANSI C62.41 Cat. A Transient Protection
Dynamic End-of-Lamp-Life Sensing
Remote Mounting up to 7 fee
t
.
1
Data based on PENTRON HO lamp type. See the
SYLVANIA QUICKTRONIC Electronic Ballast Technology
and Specification Guide (ECS-ELECTRONIC) for other
lamp combinations.
Performance Guide
Specifications
1
Ordering Guide
System Life / Warranty
<10% THD Electronic T5 HO Fluorescent Dimming Systems
Dimensions:
Overall: 425mm L x 30mm W x 30mm H
Mounting: 415 mm
Wiring:
Push-in connectors (no leads provided)
Use 18AWG solid copper wire only
Packaging: 
Quantity: 20 
Weight: 1.0 lbs ea. (approx)
Input
Input
Rated
2,3
Ballast
3
Input
3
System
Item
Voltage
Current
Lamp
1
Lumens
No. of
Factor
System
3
Wattage
Efficacy
Number
Description
(VAC)
(AMPS)
Type
(lm)
Lamps
(BF)
Lumens
(W)
(lm/W)
49671
QT1x54/120PHO-DIM
120
0.54
FP54T5HO
5000
1
1.00
5000
62
81
0.01
50
8
49672
QT1x54/277PHO-DIM
277
0.23
FP54T5HO
5000
1
1.00
5000
61
82
0.01
50
8
49673
QT2x54/120PHO-DIM
120
1.07
FP54T5HO
5000
2
1.00
10000
120
83
0.01
100
18
49674
QT2x54/277PHO-DIM
277
0.45
FP54T5HO
5000
2
1.00
10000
117
85
0.01
100
18
1
Also compatible with other manufacturer’s equivalent lamp types that meet ANSI standards.
2
Rated lamp lumens and performance data based on PENTRON
®
HO lamps.
3
At 35°C lamp ambient temperature
Item Number
49673  QT  2 x 54 /  120  PHO-DIM
System Type –  PHO-DIM
QUICKTRONIC
Line Voltage
Number of Lamps (1, 2)
Primary Lamp Wattage
Dimming Control
Specifications
2
Specifications subject to change
without notice.
QUICKTRONIC products are covered by
our QUICK 60+
®
warranty, a compre-
hensive lamp and ballast system
warranty. For additional details, refer
to our QUICK 60+ warranty bulletin.
Dimming Control
2
1-10Vdc 
two wire control (10V = full output,
1V = minimum output)
Line Voltage Protection:
Ballast goes to 90% if line voltage is
inadvertently applied to control leads.
Ballast will source up to 0.5mA for
control purposes. May be wired as
Class 1 or Class 2 circuit.
QUICKTRONIC HELIOS ballasts are
compatible with a wide range of
0–10V controllers available from
various manufacturers. A list of
controls companies is on pages 
64-65. (Controls list literature
ordering code ECS041.)
LAMP
Black
DIMMABLE BALLAST
L
N
+
-
White
Violet
Gray
1
2
3
4
1-10Vdc control input
Red
Red
Blue
Blue
 Class 1 or Class 2 Circuit
QUICKTRONIC 2x54PHO-DIM
Black
DIMMABLE BALLAST
LAMP 2
LAMP 1
L
N
+
White
Violet
Gray
1
2
3
4
5
6
7
1-10Vdc control input
Red
Red
Blue
Blue
Yellow/Wht
Yellow
Yellow
 Class 1 or Class 2 Circuit
(0-10V)
PHO-DIM
Normal Ballast Factor
A list of compatible controllers and wiring examples are on pages 64 & 65.
QUICKTRONIC
®
1x54PHO-DIM