INSTALLATION   INSTRUCTIONS   12V  LOW  VOLTAGE
AND  120V  MOUNTING   FRAME
INSTRUCTION  SHEET
12-01/Rev-04
ISF:302
FIG.1
FIG.2
FIG.3
FIG.4
MOUNTING
FRAME
MOUNTING
BAR
MOUNTING
BAR
BUILT-IN
NAILER
WOOD
JOIST
MOUNTING
BAR
MOUNTING
FRAME
"PRY-OUT"
PLUG
FLEXIBLE
WIRE
WIRE
CLAMP
JUNCTION
BOX
FIG.11
ANCHOR
CLIP
MOUNTING BAR
EXPANDABLE
T-BAR
FRAME
A. MOUNTING  BAR:  For  new  ceilings
Note-1: The  mounting bars are extensible from 12-1/2” to 27-1/4”
max. for 302MR, 302ES model and 29” for 402MR model.
Note-2:  For  off-centre  installation,  use  the  20”  expandable
mounting  bars  (Nº1964,  order  separately).
1. Insert the mounting bars into the proper openings on the short
side or the long side of the mounting frame. (Fig.2)
2. Align the mounting bar with the bottom edge of the wood joist.
(Fig.1)
3. Push in the built-in nailer. (Fig.1)
B. MOUNTING  BAR:  For  a  T-Bar  ceilings
1. Position the notch in the mounting bar on top of the
T-bar  frame.  (Fig.10)
2. Fasten with the metal wire or other. (Fig.10)
Note: When used with the 20” expandable mounting bars
(Nº1964),  use  the  anchor clip for  T-bar frame  (Nº1956,  order
separately).  (Fig.11)
C. MOUNTING  FRAME:
1. Install the locking clip. (Fig.3)
Note-1:  The  locking  clip  is  also  available  separately
(Nº0098,  order  separately).
Note-2:  To  lock  more  securely  into  place  fold  the  locking  tabs.
(Fig.2)
D. WIRE-IN:
1. Remove the appropriate "Pry-out plug".
2. Insert the supply lead into the junction box:
a) If using FLEXIBLE CONDUIT: Use a BX connector (not provided).
b) If using FLEXIBLE WIRE: Insert under the wire clamp. (Fig.4)
3. Connect the ground lead. (Fig.5,6,7)
4. Connect the white leads (NEUTRAL) together, and the black leads
(120V)  together. (Fig.5,6,7)
E. CEILING:
1. Cut a hole in the ceiling (3-3/4” for Model 302 or 4-3/4” for
Model 402), using the mounting frame as template (if applicable).
(Fig.8)
2. Use the  screws to adjust the  housing height.  Note: Ensure
that  the  housing  is  level  with  the  ceiling. (Fig.9)
3. Tighten  the  screws  when  completed.  (Fig.9)
CAUTION:  The  socket  must  not  be  used  for  temporary
lighting,  a  protective  glass  is  required  for  the  lamp.
TRIM:
Install the trim using the appropriate sheet.
NOTE:  WARNING  RISK  OF  FIRE
Transformer  contains  fixture  thermal  protector.  Use  only  replacement
transformer  obtained  from  LIGHTOLIER.
MOUNTING
BAR
FIG.10
NOTCH
T-BAR
FRAME
LOCKING
TAB
LOCKING
CLIP
METAL
WIRE
JUNCTION
BOX
INPUT  (120V)
NEUTRAL  (white)
GROUND
LAMP
LOW  VOLTAGE
TRANSFORMER
WHITE
BLACK
THERMAL
PROTECTOR
JUNCTION
BOX
THERMAL
PROTECTOR
LAMP
INPUT  (120V)
GROUND
NEUTRAL  (white)
BLACK
NEUTRAL
WHITE
WHITE
BLUE
FIG.8
FIG.9
HOUSING
302MR  -  402MR
302ES
FIG.5
(302MR)
FIG.6
(302ES)
JUNCTION  BOX
LAMP
LOW  VOLTAGE
TRANSFORMER
THERMAL
PROTECTOR
NEUTRAL  (white)
GROUND
BLUE
BLACK
BLACK
INPUT  (120V)
NEUTRAL  (white)
FIG.7
(402MR)
READ  AND  UNDERSTAND  THESE  INSTRUCTIONS  BEFORE  INSTALLING  FIXTURE
This  fixture  is  intended  for  installation  in  accordance  with  National  Electrical  Code  or  Canadian  Electrical
Code  (as  applicable)  and  local  regulations.  To  ensure  full  compliance  with  local  codes  and  regulations,  check  with  your  local
electrical  inspector  before  installation.  To  prevent  electrical  shock,  turn  off  electricity  at  fuse  box  before  proceeding.
Retain  these  instructions  for  maintenance  reference.
SCREWS