Lightolier C12E28VN Fascicule
Calculite
®
HID Downlight
C12E28VN
Page 1 of 2
12" Aperture, ED28 (Enclosed) Metal Halide, Narrow Beam
Job Information
Type:
Job Name:
Cat. No.:
Cat. No.:
Lamp(s):
Notes:
Notes:
Lightolier
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
2" (50 mm) max.
Ceiling Thickness
Ceiling Thickness
Vertical
Adjustment:
5/8" (16 mm) to
2 7/8" (73 mm)
Adjustment:
5/8" (16 mm) to
2 7/8" (73 mm)
3
1
10
6
5
9
8
4
2
11
7
12" (305 mm) Dia.
18-3/4"
(376 mm)
13-1/4" (337 mm) Dia.
11"
(280 mm)
Top View
21-1/4" (540 mm) 175-250W
23-3/4" (603 mm)
320-400W
20" (508 mm) to 30" (762 mm)
16-3/8" (416 mm)
10-3/4"
(273 mm)
13" (330 mm)
Ceiling Cutout: 12 9/16” (256 mm) Dia.
Reflector Trim
Frame-In Kit
Lamp (Enclosed, Coated)
C12E28VN CLW
Specular Clear, White Painted Flange.
CLP
Specular Clear, Matching Flange.
CCDW
Comfort Clear Diffuse, White Painted Flange.
CCDP
Comfort Clear Diffuse, Matching Flange.
CCZW
Champagne Bronze, White Painted Flange.
CCZP
Champagne Bronze, Matching Flange.
C1217MHPU Magnetic Pulse Start, 120V/277V
175W ED28, BT28, PS MH
C1225MHPU Magnetic Pulse Start, 120V/277V
250W ED28, BT28, PS MH
C1232MHPU Magnetic Pulse Start, 120V/277V
320W ED28, BT28, PS MH
C1240MHPU Magnetic Pulse Start, 120V/277V
400W ED28, BT28, PS MH
C1217MHU Magnetic, 120V/277V
175W ED28, BT28, MH
C1225MHU Magnetic, 120V/277V
250W ED28, BT28, MH
C1240MHU Magnetic, 120V/277V
400W ED28, BT28, MH
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides narrow
beam optics ideal for high ceilings. Also available in wide beam, see
C12E28VW specification sheet.
C12E28VW specification sheet.
2. Aperture Cone: Low brightness with 40° cut-off to lamp. Specular Clear or
Comfort Clear™ Diffuse, or champagne bronze self-flanged in painted white
or aperture-matching polished flange. Consult factory for other finishes.
or aperture-matching polished flange. Consult factory for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive
during re-lamping.
4. Socket Cup: Heat dissipating, die-cast aluminum, pre-wired with mogul base
porcelain socket with nickel plated screw shell. Postive locking attachment
without tools to reflector assures proper optical alignment of lamp.
without tools to reflector assures proper optical alignment of lamp.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel. Includes the pre-installed
mounting bars.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
notches allow consistent alignment of multiple fixtures.
7. Retention Springs: Rust resistant springs secure cone for quick, tool-less
installation.
8. Frame Vertical Adjustment: Vertical adjustment mechanism accommodates
mounting to virtually any ceiling system using mounting bars (provided, or
1/2" EMT tubing (by others). Single locking feature secures all adjustments.
Alignment holes and markings allow fixture to be preset prior to installation.
1/2" EMT tubing (by others). Single locking feature secures all adjustments.
Alignment holes and markings allow fixture to be preset prior to installation.
9. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long
and lock securely into position. Built-in locking tabs provide positive attachment
to common T-bar systems. Self-centering feature simplifies installation in 24"
O.C. grid systems. Attaches to steel or wood joists without accessories.
to common T-bar systems. Self-centering feature simplifies installation in 24"
O.C. grid systems. Attaches to steel or wood joists without accessories.
10. Ballast: Pulse Start
11. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
11. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
12. Thermal Protector: Meets NEC and UL requirements. Do not install
insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, CWA or
Super CWA (pulse start) circuit type, high power factor, sound rating “B” (175W
and 250W PS)/sound rating “C” (others), -20°F minimum starting Temperature,
Type 1 Outdoor rating.
Super CWA (pulse start) circuit type, high power factor, sound rating “B” (175W
and 250W PS)/sound rating “C” (others), -20°F minimum starting Temperature,
Type 1 Outdoor rating.
Electrical (cont.)
Ballast
ANSI Code Voltage
Max. Amps
Input Watts
175W PS MH
M137
120/277
2.20/0.90
205
250W PS MH
M138
120/277
2.80/1.20
290
320W PS MH
M132
120/277
3.40/1.50
370
400W PS MH
M135
120/277
4.10/1.80
465
175W MH
M57
120/277
2.00/0.90
205
250W MH
M58
120/277
2.60/1.10
290
400W MH
M59
120/277
3.90/1.70
460
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“.
Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).
Chicago Plenum: Consult Factory.
Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W.
For 320W/400W, install fixtures with minimum spacing: 4 feet from center-to-
center of adjacent luminaries; 3 inch from top of luminaire to overhead building
member;2 feet from luminaire center to side building member.
For 320W/400W, install fixtures with minimum spacing: 4 feet from center-to-
center of adjacent luminaries; 3 inch from top of luminaire to overhead building
member;2 feet from luminaire center to side building member.