Lightolier FBP90 Fascicule

Page de 1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0308
Job Information 
Type:
Job Name: 
Cat. No.: 
Lamp(s): 
Notes:
 
FBP Series Fluorescent Emergency Ballast
  FBP90
Page 1 of 1 
One Lamp Operation 600 Lumens
Lightolier is a Philips group brand
Nickel Cadmium Battery
The FBP Series quickly converts standard fluorescent luminaires into emergency luminaires.
9.4”
(23.9 cm)
2.4”
(6.1 cm)
1.5”
(3.8 cm)
Features
1.  Lamp Operation: Operates the following lamp types: T8 linear fluorescent, 
T12 linear fluorescent, T9 circline, T12 U-bent, T5 long compact fluorescent. 
See Lamp Operation and Performance table for specific lamp performance 
and operation.
2.  Illumination: Provides 90 minutes of emergency illumination, and produces 
500-600 lumens initial emergency light output. Can be used with most 17w 
to 40w (2’ - 4’) T8, T10 or T12 fluorescent lamps without integral starters 
including U-shaped, HO, VHO, circline, energy saving, and 4 pin compacts. It 
is also compatible with most 1, 2, 3 and 4-lamp electronic, standard, energy 
saving and dimming AC ballasts.
3.  Housing: Constructed of 20 gauge steel with a white high temperature pow-
der coat paint finish. Slim housing allows for wireway channel mounting on 
most recessed luminaires.
4.  Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with AC indicator lamp and test 
switch.
5.  Battery: Maintenance free, sealed nickel cadmium battery has an estimated 
service life of 10 years, and an operating temperature range of 32°F (0°C) to 
131°F (55°C). 
 
6.  Input Power Requirements: 4 watts max.
7.  Warranty: Electronics: 1 year; Battery: 1 year.
Code Compliance
UL 924 listed.
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz. 
Contact factory for other input voltages and frequencies. 
DL = UL Damp Location Listing
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire
RTS = Single gang aluminum faceplate pre-drilled to accommodate remote installa-
tion of test switch and pilot light
Lamp Operation and Performance
   
 
 
   Non-Emer.  Emer. Op. 
 
     
 
 
Max. 
Max. 
Emer 
 Lamp 
 
Base 
 Lumen 
Lumen 
Lamp
 Type 
Watt.  
Type 
Output 
Output 
Operation
F20T12 
20  G13/Med Bi-Pin  1275 
500 - 600 
One
 F30T12 
30  G13/Med Bi-Pin  2350 
500 - 600 
One 
 F40T12 
40  G13/Med Bi-Pin  2650 
500 - 600 
One
F40T12/U 
40  G13/Med Bi-Pin  3100 
500 - 600 
One
 F48T10 
110  R17D/Recessed  6200 
500 - 600 
One
 F17T8 
17  G13/Med Bi-Pin  1350 
500 - 600 
One
 F25T8 
25  G13/Med Bi-Pin  2150 
500 - 600 
One
 F32T8 
32  G13/Med Bi-Pin  2950 
500 - 600 
One
 F32T8/U 
32  G13/Med Bi-Pin  2700 
500 - 600 
One
F40T8 
40  G13/Med Bi-Pin  3725 
500 - 600 
One
 FC6T9 
20 
G10Q/4 Pin 
800 
500 - 600 
One
 FC8T9 
22 
G10Q/4 Pin 
1100 
500 - 600 
One
 FC12T9 
32 
G10Q/4 Pin 
1950 
500 - 600 
One
 FC16T9 
40 
G10Q/4 Pin 
2700 
500 - 600 
One
 F39/36BX 
39 
2G11/4 Pin 
2850 
500 - 600 
One
 F40/30BX 
40 
2G11/4 Pin 
3150 
350 - 450 
One
Notes: 
1.  Maximum non-emergency lumen output can vary based on lamp manufacturer, ambient operating 
temperature, and ballast manufacturer.
2.  Maximum emergency lumen output is based on total output of one or two lamps, and can vary 
based on lamp manufacturer and ambient operating temperature.
3.  Maximum emergency lumen output is supported for a full 90 minutes of operation.
4.  Consult factory for compatibility, operation and performance of lamp types not listed.
Complete Fixture consists of ballast unit. Select options and accessories below.
Model # 
Max. Lumens 
Lamp Operation 
 
FBP90 
600 
One