Lightolier C4120 Fascicule

Page de 1
Ceiling Cutout: 5 1/16” (129 mm) Dia.
Frame-In Kit
Reflector Trim
C4120
Open
Open
Adjustable
Open
Lensed
Downlight
Downlight
Accent
Wall Washer/Downlight
Wall Washer
C4AD
C4P20D
C4P20A
C4AW
C4P20L
100W A19, MB19
50W PAR20
50W PAR20
100W A19, MB19
50W PAR20
100W BT15
75W PAR16
75W PAR16
100W BT15
75W PAR16
75W BR19, R20
Calculite
®
Evolution Recessed Downlight
C4120
Page 1 of 1
4 1/2” Aperture Incandescent 120V Non-IC Frame-In Kit
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Options and Accessories (continued)
Wood Joist Telescoping Bars:
7994 - set of (2)
Chicago Plenum:
Add LC to frame suffix.
Labels
UL Listed (suitable for damp locations), I.B.E.W.
US Patent No. 5,957,573. Other US and Foreign Patents Pending.
12 1/2"
9 1/2" Dia.
1/4" min. - 2 3/4" max.
3"
4
*7 3/4" min. is for 
up to 3/4" thick ceiling.
1 1/4" Max. Ceiling Thk.
8 1/4" max.
7 3/4" min.*
6
7
3
7 3/4"
12 3/8" 
1
2
5
7" 
Features
1. Housing: Steel, 0.03" (22 ga.). Top Cover (removable) Aluminum, 0.04" 
(14 ga.). Matte black finish.
2. Mounting Frame: Die-cast aluminum for dry or plaster ceilings. 
3. Retaining Springs: Precision-tooled steel springs secure reflector trim to
mounting frame for quick, tool-less installation.
4. Mounting Brackets: Galvanized steel, 0.06" (16 ga.). Adjust from inside
and outside of fixture. Use 3/4" or 1 1/2" lathing channel, 1/2" EMT (by oth-
ers), or optional Lightolier mounting bars.
5. Snap-In Connectors: Keyed to accept power and socket harnesses which
are provided with reflector trim.
6. Junction Box: Galvanized steel .063" (14 ga.). UL Listed for maximum of 8
No. 12 AWG 90°C through branch circuit conductors. Accessible from inside
and outside of fixture. Outside J-Box door is hinged for maximum opening.
Snap-in plug is provided on inside cover for quick connection to power harness.
7. Thermal Protector: Meets NEC and UL requirements. Insulation must be
kept 3" away from fixture sides and wiring compartments and must not be
placed above fixture in a manner which will entrap heat.
8. Reflector Trim: Compatible reflector trims are listed above. See separate
reflector trim specification sheets for complete catalog numbers and details.
Options and Accessories
Mounting Bars:
1950 - 18” set of (2)
1951 - 27” set of (2)
T-Bars Anchor Clips:
1956 - set of (4) for use w/bars above.