Lightolier COL/EOL Fascicule

Page de 2
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0608
Job Information 
Type:
Job Name: 
Cat. No.: 
Lamp(s): 
Notes:
 
COL/EOL Series Forward Throw Cutoff Luminaire
 
COL/EOL
Page 1 of 2 
Type 4 Distribution, Integral 35-Watt Emergency Xenarc Lamp
Lightolier is a Philips group brand
Features
1.   Illumination:  Normal illumination is provided by one 100-watt, high-
pressure sodium lamp or one 100-watt, metal halide lamp, combined 
with a polished specular aluminum reflector with Type 4 distribution.  
Normally on illumination may be switched or photocell controlled.  
Emergency illumination is accomplished with a 35-watt, instant strike 
Xenarc® lamp, powered from a remote emergency battery unit (sold 
separately).
2.  Housing:  All housing components are of premium die-cast aluminum 
construction with a durable dark bronze powder coat finish.  Stainless 
steel torx head T25 tamperproof hardware included.
3.  Electronics:  AC Only - HX/HPF core/coil HID ballast, spring loaded 
4KV pulse rated HID socket, medium base.
 
Emergency Operation - 35-watt, instant strike Xenarc lamp (requires 
a remote emergency power source of 12 VDC, 35-watts minimum)
4.  Operating Temperature Range - Wet location: -40°F (-40°C) to 
104°F (40°C)
5.  Recommended Emergency Battery Units (sold separately) -  
Indoor/Outdoor** Recessed Ceiling Mount - C3250LWDLTD
  Indoor Surface Mount - E4250LWTD
6.  Electrical Specifications:  120/208/240/277 VAC, 60 HZ, multi-tap 
input wiring; 130-watts power consumption
 
7.  Warranty:  Five-year warranty (excludes lamps.)
Code Compliance
Wet location listed
ETL listed to UL 924 standards
ETL listed to UL 1598 standards
ETL listed to CSA C22.2 No 141-02 standards
ETL listed to CSA C22.2 No 250.0-04 standards
The COL Series is designed to provide normal and outdoor egress lighting in a single fixture.
How to Specify 100w HPS or 100w MH luminaire with/without 35w Xenarc® lamp:
9.25”
(23.5cm)
17”
(43.2cm)
7.25”
(18.4cm)
COL
SERIES
COL = Forward Throw
           Cutoff  Luminaire
BZ
AC LAMP TYPE
1H = 100-Watt, High-Pressure Sodium Lamp
1M = 100-Watt, Metal Halide Lamp
EMERGENCY FUNCTION 
1
Blank = AC Fixture, No Emergency Lamp
EM = 35-Watt, Instant Strike
 
     Xenarc
®
 Lamp
HOUSING COLOR 
2
BZ = Dark Bronze
NOTES:
1) Requires a remote emergency power 
source of 12 VDC and at least 35-watts and 
TD to cover re-strike period.
2) Custom Colors available, consult factory.
3) See C3 sheet for product specifications
4) See E4 sheet for product specifications.
* The COL Series emergency lamp requires a remote 12 VDC power source.
** The C3250LWDLTD may be used outdoors in locations where the 
product is not directly exposed to the elements.
How to Specify 100w HPS or 100w MH luminaire with 35w Xenarc® lamp and remote C3250LWDLTD emergency module:
EOL
SERIES
EOL = Forward Throw
           Cutoff  Luminaire
BZ
AC LAMP, 35W AND C3 MODULE
HRW(B)= 100-watt High Pressure Sodium lamp & White (Black) C3 EM Module 
3
MRW(B)= 100-watt Metal Halide lamp & White (Black) C3 EM Module 
3
 
HOUSING COLOR 
2
BZ = Dark Bronze
How to Specify 100w HPS or 100w MH luminaire with 35w Xenarc® lamp and remote E4250LWTD emergency module:
EOL
SERIES
EOL = Forward Throw
           Cutoff  Luminaire
BZ
AC LAMP, 35W AND E4 MODULE
HSW(B) = 100-watt High Pressure Sodium lamp & White (Black) E4 EM Module 
4
MSW(B)= 100-watt Metal Halide lamp & White (Black) E4 EM Module 
4
 
HOUSING COLOR 
2
BZ = Dark Bronze