Lightolier C6P38MH Fascicule

Page de 2
Calculite
®
HID Downlight
C6P38MH
Page 1 of 2
6" Aperture, PAR38 Ceramic MH
5 7/8" (149 mm) Dia.
4
7
3
8
10
5
6
9
2
9
1
5 5/8" (143 mm) Dia.
Vertical Adjustment: 
5/8" (16 mm) to 
2 7/8" (73 mm)
2" (50 mm) max.
Ceiling Thickness
11-1/4" 
(286 mm)
7-1/4" (184 mm) Dia.
18-5/8" (473 mm)
20" (508 mm) to 30" (762 mm)
10-7/8" 
(276 mm)
9-3/4" 
(248 mm)
10-1/2" 
(267 mm)
Top View
(Magnetic Ballast)
7-1/4" 
(184 mm)
11" (280 mm)
(100W)
10-7/8" 
(276 mm)
Top View
(Electronic Ballast)
9-3/4" 
(248 mm)
20" (508 mm) to 
30" (762 mm)
Ceiling Cutout: 6 9/16”(167 mm) Dia.
Reflector Trim
Frame-In Kit
Lamp
C6P38MH CLW
Specular Clear, White Painted Flange.
CLP
Specular Clear, Matching Flange.
CCDW
Comfort Clear Diffuse, White Painted Flange.
CCDP
Comfort Clear Diffuse, Matching Flange.
CCZW
Champagne Bronze, White Painted Flange.
CCZP
Champagne Bronze, Matching Flange.
MG
Black Multi-Groove, White Molded Trim Ring.
.
C670MHE1
Electronic 120V
70W PAR38
Ceramic Metal Halide
C670MHE2
Electronic 277V
70W PAR38
Ceramic Metal Halide
C610MHE1
Electronic 120V
100W PAR38
Ceramic Metal Halide
C610MHE2
Electronic 277V
100W PAR38
Ceramic Metal Halide
C670MHU
Magnetic 120V/277V
70W PAR38
Ceramic Metal Halide
C610MHU
Magnetic 120V/277V
100W PAR38
Ceramic Metal Halide
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Features
1. Reflector Trim: Clear anodized aluminum, 0.040” (16-ga.). Provides 45°
visual cut-off to lamp and lamp image; self-flange in painted white or 
aperture-matching polished flange. Consult factory for other finishes.
2. Mulit-Groove Baffle: One piece seamless aluminum. Sharply detailed con-
centric rings, black finish. Permanently fastened to specular clear reflector. 
3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated
socket. Snaps onto upper reflector for secure attachment without tools;
assures proper lamp alignment to optics for consistent performance.
4. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed
mounting bars. 
5. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
6. Retention Springs: Rust resistant springs secure cone in place for quick,
tool-less installation.
7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed
mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures
all adjustments. Alignment holes and markings allow fixture to be pre-set
prior to installation.
8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30"
long and lock securely into position. Built-in locking tabs provide positive
attachment to common T-bar systems. Self-centering feature simplifies
installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).
Accessible from below for inspection and/or replacement without tools.
10. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18
non-consumer equipment, shut-down circuit at end of lamp life, sound rating 
"A", -5°F minimum starting temperature, Type 1 outdoor rating.
Ballast
ANSI Code
Voltage
Max. Amps
Input Watts
70W MH
M98/M143
120/277
0.67/0.28
78
100W MH M90/M140
120/277
0.90/0.43
110
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, 
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting
temperature, Type 1 Outdoor rating.
Ballast
ANSI Code
Voltage
Max. Amps
Input Watts
70W MH
M98/M143
120/277
1.90/0.80
94
100W MH M90/M140
120/277
2.40/1.10
125
Options and Accessories
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast)Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V)
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W.