Lightolier C4LVE1RM Fascicule

Page de 1
WIRE GA.
NOTE: 
FIGURE 4 
FIGURE 3 
FIGURE 5 
FIGURE 6 
FIGURE 2 
FIGURE 1 
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  To 
assure full compliance with local codes and regulations, check with your local electrical inspector before 
installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 
Retain these instructions for maintenance reference. 
INSTALLATION PROCEDURE FOR: C4LVE1RM & C4LVRMNT REMODELER KITS 
WARNING: (RISK OF FIRE) 
DO NOT INSTALL INSULATION WITHIN 3 INCHES OF FIXTURE SIDES OR WIRING 
COMPARTMENT, NOR ABOVE FIXTURE IN SUCH A MANNER SO AS TO ENTRAP HEAT.
 
WARNING: 
USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER.  USE OF OTHER MANUFACTURES’ REFLECTOR 
TRIMS MAY VOID THE UNDERWRITERS LABRATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
 
INSTRUCTION SHEET NO.
IS:C4LVE1RM
B0401 
Page 1 of 1
 COMPANY
631 Airport Road, Fall River, MA 02720 
STEP ONE: 
Use aperture sticker provided as a template and cut a 5" diameter hole in the ceiling. 
Cut to outside edge of sticker. Hook the metal frame onto the ceiling and connect supply cable in 
the junction box.  As shown in
 
FIGURE 1.
 
 
STEP TWO: 
(C4LVE1RM – Remodeler Kit with built in transformer)
 
Wiring: For non-metallic cable, open hinged knockout to allow cable to enter into junction box. 
Push cable through clamp. Wire to supply leads. Bare fixture lead and/or green fixture lead to 
supply ground. White fixture lead to neutral supply lead. Black fixture lead to hot supply lead. Use 
wirenuts (local hardware item). Place all electrical connections in the junction box and close the 
junction box cover. 
 
STEP TWO: 
(C4LVRMNT – Remodeler Kit - No transformer supplied)
 
Caution: 
Wiring for 12V supply connection ONLY.
 
(See NOTE below)
 
Connect bare fixture lead to supply ground. Black and white fixture leads to 12V supply.
Use wirenuts (local hardware item).
 
STEP THREE: 
Install the metal frame through the hole and pull the frame strap down. 
As shown in
 
FIGURE 2 & 3.
 
 
STEP FOUR: 
Insert the housing straight up into frame opening while pulling down on the frame 
strap. Once housing is flush to ceiling, bend frame strap into housing to secure. 
As shown in
 
FIGURE 3 & 4.
 
 
STEP FIVE: 
Push both ceiling retention clips outward to engage into track, then pull clips down until they 
contact the metal frame. As shown in
 
FIGURE 4.
 
 
STEP SIX: 
Tighten both the fine adjustment screws located at the top of the housing tracks until the 
assembly is secure. As shown in
 
FIGURE 5.
 
 
STEP SEVEN: (Trim Installation) 
Insert socket connector into housing connector. Assemble socket and lamp to trim and insert 
reflector trim into fixture housing, as shown in
 
FIGURE 6.
 
Push straight up
 
until flush with ceiling. 
See separate instructions supplied with trim for complete installation and removal of trim.
 
 
REMOVAL:
  
(For access to junction box and transformer).
 
With trim removed, loosen adjustment screws at top of tracks. Pull frame strap down. Squeeze 
the vertical side tabs on clips together, and push clip up to top of track while pulling down on 
frame strap. When clips are loose, pull housing straight down
NOTE: 
(C4LVRMNT ONLY) Follow the max. wire length 
recommended below to minimize voltage drop. Voltage 
drop will affect the brightness and color of the light
.
WIRE GA.
WIRE LENGTH (FT.)
18
16
14
12
11
17
28
45