Lightolier 8031 Fascicule

Page de 2
Instruction Sheet Number 
IS:8031
Page 1 of 2 
Installation of Calculite
®
 Compact Fluorescent Downlights and Wall Washer Reflector Trims
Lightolier 
a Genlyte company 
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • B0306
Read and understand these instructions before installing fixture.
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and 
regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
Warranty information on back – retain this sheet.
REFLECTOR OR LENS TRIM
1
.
G
I
F
2
 .
G
I
F
Reflector or
Lens Trim
White
Trim
Ring
FIG. 4
FIG. 3
White 
Trim
Ring
INSTALLATION OF LENS WALL WASHER 
AND OPEN WALL WASHER
required.
REFLECTOR OR LENS TRIM
A. INSTALL WHITE TRIM RING (FIG. 1, 2, 3 & 4)
NOTE: Omit this section if reflector is self-flanged.
1.  For overlapping trim installation (Fig 1) slip 
White Trim Ring  
  over 
Reflector, as shown in Fig 2 & 3.
2.  For flangless trim installation (Fig 4), 
White Trim Ring is not required.
B. SNAP-IN 
(FIG. 5)
  Engage 
Retaining Spring into Slots in Reflector (see FIG. 5)  
  following chart below. See Frame-in kit for lamp information.
C. PUSH-UP REFLECTOR
 (FIG. 6 & 7)
  Tilt 
Reflector and insert Socket Cup into ceiling opening on side
  opposite 
Junction Box. Pivot Reflector and push it up into
  ceiling (FIG 6).
 
NOTE:
 To remove 
Reflector, disengage the Socket Cup by 
  depressing the 
Retaining Spring (FIG. 5). Turn Reflector 
  counterclockwise while pulling downward. After starting, 
  use both hands to remove, see FIG 7.
D. LAMPING (FIG. 8)
  NOTE: See 
Socket Cup Label for lamping information.
  Line up Lamp Pins with 
Socket, tilt lamp base to engage, then bring
  lamp to horizontal position and push into
 Socket (FIG. 8). To relamp,
  CAREFULLY PULL STRAIGHT OUT OF SOCKET WITH ONE FINGER
  PLACED ON THE TOP OF THE LAMP.
CARE AND MAINTENANCE OF ALZAK REFLECTOR
If you must handle the anodized or Alzak reflectors, we recommend using
clean white or plastic film gloves to avoid fingerprints.
Anodized or Alzak surfaces can be cleaned by the following methods:
1.  Wipe off with a soft, clean, dry, lint-free cloth.
2.  Wipe off with a soft clean cloth dampened in mild detergent.
3.  Wipe off with a clean cloth dampened with a solution of wetting
  agent and water (such as 2 oz. per gallon “Pluronic L62-LF” by
  Wyandotte Products); then wipe dry.
4. Or use a liquid wash such as Glass Wax
®
. Avoid gritty cleaning agents.
7
 .
G
I
F
6
 .
G
I
F
Socket
Cup
Reflector
Junction
Box
To Remove
FIG. 8
FIG. 5
Reflector
Retaining Spring
Socket Cup
Slot
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8