READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  To 
assure full compliance with local codes and regulations, check with your local electrical inspector before 
installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 
Retain these instructions for maintenance reference.
INSTALLATION PROCEDURE FOR: 4X4, 4X9, AND 9X9  
MATRIX SERIES RECESSED DOWNLIGHTS, FOR CHICAGO PLENUM
INSTRUCTION SHEET NO.
    IS:4X4LC
A0602 
Page 1 of 2
 COMPANY
631 Airport Road, Fall River, MA 02720 
90
° 
A.  FRAME-IN AND WIRE-IN 
 
Install FRAME-IN KIT (FIK) using ADJUSTABLE MOUNTING BRACKETS (Fig.’s 1-3).  Fixture must be secured to 
structural ceiling members.  Connect to supply leads; white fixture lead to neutral (white) supply lead, black fixture 
lead to hot supply lead, bare copper and/or green insulated wire(s) must be connected to supply ground. Use 
wirenuts (local hardware items). Place all electrical connections in the J-BOX and close cover. 
CAUTION: (RISK OF FIRE) DO NOT INSTALL INSULATION ABOVE NOR WITHIN 3 INCHES (76mm) OF ANY 
PART OF THE LUMINAIRE (FIXTURE) 
CAUTION: USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER.  USE OF OTHER MANUFACTURERS’ REFLECTOR 
TRIMS MAY VOID THE UNDERWRITERS LABRATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD. 
ANCHOR CLIP 
MOUNTING BAR 
T-BAR 
WIRE 
FIG. 4
FIG. 5
For suspended T-bar ceilings: T-bar ANCHOR CLIPS 
accessory  No. 1956 (order separately) may be used with 
18” or 27” MOUNTING BARS (Fig. 4), or simply wire 
MOUNTING BARS, EMT TUBING, or CHANNELS to 
ceiling members (Fig. 5).  
FIK must be securely attached to and unable to lift from 
ceiling members after installation is complete. 
For wood joist construction:  Mounting bars may be 
used to secure FIK. to joists (Fig. 6). MOUNTING BARS 
may be bent where required to allow precise placement 
of FIK between joists.  Use nails to secure to joists. 
ADJUSTMENT 
SCREW 
ADJUSTMENT 
SCREW 
ADJUSTMENT 
SCREW 
FIK. 
HOUSING
ADJUSTABLE 
MOUNTING  
BRACKET 
MOUNTING 
BAR 
3/4” OR 1-1/2” 
CHANNEL 
(BY OTHERS) 
1/2”  EMT 
(11/16” OD) 
(BY OTHERS) 
ADJUSTABLE 
MOUNTING  
BRACKET
ADJUSTABLE 
MOUNTING  
BRACKET 
FIG. 1
FIG. 2
FIG. 3
FIK. 
HOUSING
FIK. 
HOUSING 
BALLAST
MOUNTING BAR
J-BOX 
NAILS
JOISTS 
MOUNTING BAR ordering information: 
18” long: Cat. No. 1950 
Note: If FIK is to be used with a WALL-WASH LOUVER TRIM 
(Fig. 7), FIK must be installed with either J-BOX side or 
BALLAST side parallel to wall to be washed. 
 
 
 
              Direction of wall to be washed 
FIG. 6 