Elation Professional 216 Manuel D’Utilisation

Page de 44
 
 
ELAR 216 Panel
 
©Elation Professional, Los Angeles Ca. 
18 
 
www.ElationLighting.com
   
In the case of the ELAR 216 Panel ™, which is up to a nine channel fixture, you should set 
the starting DMX address of the first unit to 1, the second unit to 10 (9 + 1), the third unit to 
19 (9 + 10), and so on. 
 
Note: During start-up the ELAR 216 Panel ™ will automatically detect whether a DMX data 
signal is being received or not. If a DMX data signal is being received, the display will show 
"A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a DMX 
signal the display will flash "A.XXX" (XXX representing the actual DMX address).   
 
If your fixture is connected to a DMX controller and the display is flashing (not receiving a 
DMX signal), please check the following: 
-    The  3-pin  or  5-pin  XLR  plug  (cable  with  DMX  signal  from  controller)  may  not  be 
connected or is not inserted completely into the DMX input jack. 
-  The DMX controller is switched off or defective. 
-  The DMX cable from the controller merging with included IP Rated Cable adapter is 
not connected securely 
-  The DMX cable or connector is defective. 
-  A DMX terminator has been inserted into the last fixture in your DMX chain.