System Sensor 1400 Manuel D’Utilisation

Page de 4
D400-07-00                                                                                              4                                                                                              I56-279-05R
                                                                                                                                                                                                ©2004 System Sensor
System  Sensor  warrants  its  enclosed  smoke  detector  to  be  free  from 
defects in materials and workmanship under normal use and service for a 
period of three years from date of manufacture. System Sensor makes no 
other express warranty for this smoke detector. No agent, representative, 
dealer, or employee of the Company has the authority to increase or alter 
the  obligations  or  limitations  of  this  Warranty.  The  Company’s  obliga-
tion of this Warranty shall be limited to the repair or replacement of any 
part of the smoke detector which is found to be defective in materials or 
workmanship under normal use and service during the three year period 
commencing with the date of manufacture. After phoning System Sensor’s 
toll  free  number  800-SENSOR2  (736-7672)  for  a  Return  Authorization 
number,  send  defective  units  postage  prepaid  to:  System  Sensor,  Repair 
Figure 5. Removal of cover and screen for cleaning:
LOCK PRONG
REMOVABLE
SCREEN
REMOVABLE
COVER FOR
CLEANING
LOCKING
PRONGS
Maintenance
NOTE:  Before  starting,  notify  the  proper  authorities  that 
the  smoke  detector  system  is  undergoing  mainte-
nance  and,  therefore,  will  be  temporarily  out  of 
service.  Disable  the  zone  or  system  undergoing 
maintenance to prevent unwanted alarms.
The 1400 is cleaned as follows:
1.  Remove  the  detector  screen  and  cover  assembly  by 
depressing the three lock prongs on the top of the cover, 
rotating  the  cover  clockwise,  and  pulling  the  screen 
cover assembly away from the detector (see Figure 5). 
Use of the System Sensor CRT400 cover removal tool is 
recommended. 
2. Remove the screen from the cover.
3. Use a vacuum cleaner to remove dust from the screen, 
the cover, and the sensing chamber. 
4. After cleaning, snap the screen into the cover, then place 
the cover and screen assembly on the detector turning 
clockwise until it is locked in place.
5. Test the detector as described in TESTING.
6. Notify the proper authorities that the system is back on 
line.
S0143-00
Please refer to insert for the Limitations of Fire Alarm Systems
Three-Year Limited Warranty
Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. 
Please  include  a  note  describing  the  malfunction  and  suspected  cause 
of failure. The Company shall not be obligated to repair or replace units 
which  are  found  to  be  defective  because  of  damage,  unreasonable  use, 
modifications,  or  alterations  occurring  after  the  date  of  manufacture.  In 
no case shall the Company be liable for any consequential or incidental 
damages for breach of this or any other Warranty, expressed or implied 
whatsoever, even if the loss or damage is caused by the Company’s neg-
ligence or fault. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion 
may not apply to you. This Warranty gives you specific legal rights, and 
you may also have other rights which vary from state to state.