Nilfisk-Advance America SDV 4500 Manuel D’Utilisation

Page de 16
English 
 
14 
 
 
 
 
 
 
 
 
 
 
 
Symptom Possible 
cause 
Action 
No power 
Not connected / Faulty socket  
Check connection to wall socket and 
socket switch. Try in another wall socket 
 
On / Off switch not on 
Press On / Off switch which will illuminate 
when on 
 
Fuse blown 
Replace fuse with approved 13A fuse 
 Unknown  Call 
for 
service 
No steam  
Steam Control turned down fully 
clockwise 
Turn the control to half way 
 
Steamer not ready 
Wait for the “Ready to steam” light to 
illuminate 
 
Clean water tank is low (beeping 
sound& "refill" light is lit) 
Pour water into the clean water tank until 
the beeper stops. The steam handle will 
work again. 
 Unknown  Call 
for 
service 
No steam, Just water  
Steamer not ready 
Wait for the "Ready to steam " light to 
illuminate 
 
Boiler at pressure and not 
heating(temperature less than 110ºC) 
Hold the steam switch on for 
approximately one minute, ever if just 
water is coming out. This will result in the 
heater coming back on 
 Unknown  Call 
for 
service 
Steam Leaking from front 
socket 
“O” Rings split  
Change and re grease “O” Rings.  To 
avoid this happening ensure “o” rings are 
grease before every use. 
 
“O” rings worn 
Change and re grease “O” Rings.  To 
avoid this happening ensure “o” rings are 
grease before every use. 
Vacuum power low 
Vacuum operation has been selected 
on the machine  
Operate any of the handle controls, 
which will reset the motor power to full. 
Continue vacuuming  
 
 
 
 
High pitch motor noise 
 
 
 
 
Switch the machine off and empty the 
collection tank. Refill the collection tank 
with clean water to the mark and 
recommence work. 
 Unknown  Call 
for 
service 
No detergent  
Solution tank empty 
Pour cleaning solution diluted in 
accordance with the manufacturers 
instructions into the solution tank. 
 Unknown  Call 
for 
service 
 
 
 
Trouble Shooting