Nilfisk-Advance America RS 501 Manuel D’Utilisation

Page de 146
SERVICE MANUAL
ENGLISH
RS 501 
33015500(3)2008-02
21
SWEEPING SYSTEM
BROOM REPLACEMENT
NOTE
Brooms of various hardness are available. This procedure is applicable to all types of brooms.
CAUTION!
It is advisable to use protective gloves when cleaning the side brooms because there can be sharp debris 
between the bristles. 
Lift the brooms and engage the parking brake with the lever (66).
Turn the ignition key (76) to OFF position and remove it.
Remove the centre screw (A), then remove the broom (B) to be replaced. Recover the key.
Remove the screws (D), then remove the fl ange (E).
Install the fl ange (E) and secure it on the new broom with the screws (D).
Install the new broom (B) with the key, then tighten the centre screw (A).
Adjust the height of the new broom according to the procedure shown in the previous paragraph.
A
B
D
D
E
B
B
S300859
1.
2.
3.
4.
5.
6.
7.