Nilfisk-Advance America RS 501 Manuel D’Utilisation

Page de 146
ENGLISH
SERVICE MANUAL
78
33015500(3)2008-02
RS 501
LDW 1603/B2 ENGINE
ENGINE COOLANT LEVEL CHECK
Empty the hopper (3); if it contains a small quantity of waste, it is not necessary to dump it.
Drive the machine on a solid and level ground, then engage the parking brake with the lever (66).
Lift the hopper (3), according to the procedure shown in the User Manual.
Turn the ignition key (76) to OFF position and remove it.
Open the left lid (18) by releasing the fasteners (19) with the supplied key.
Remove the locking pins (28) from the housings (29) and place them into the holes (30).
WARNING!
The coolant line is pressurised; do not perform any check until the engine has cooled down and, even if the 
engine is cold, the tank plug (B) must be opened with extreme care.
Check that the coolant level in the tank (A) is between the minimum and maximum marks, according to the procedure shown 
in the Diesel Engine Manual. If necessary, unscrew the plug (B) and top up.
Coolant components:
50% of AGIP antifreeze
50% of water
After top up, tighten the plug (B).
Perform steps 3 to 6 in the reverse order.
A
B
S300894
1.
2.
3.
4.
5.
6.
7.

8.