Nilfisk-Advance America RS 501 Manuel D’Utilisation

Page de 146
ENGLISH
SERVICE MANUAL
92
33015500(3)2008-02
RS 501
CLIMATE CONTROL SYSTEM
COMPRESSOR BELT REPLACEMENT (LDW 1603/B2 engine)
Empty the hopper (3); if it contains a small quantity of waste, it is not necessary to dump it.
Drive the machine on a solid and level ground, then engage the parking brake with the lever (66).
Lift the hopper (3), according to the procedure shown in the User Manual.
Turn the ignition key (76) to OFF position and remove it.
Open the left lid (18) by releasing the fasteners (19) with the supplied key.
Remove the locking pins (28) from the housings (29) and place them into the holes (30).
Empty the dust control system water tanks (7 and 16) according to the procedure shown in the relevant paragraph.
Remove the screw (42) and open the left tank (41).
WARNING!
Open the tanks (7 and 16) only if they are empty: each tank contains 120 kg of water approximately.
Loosen the tensioning nuts (A) of the belt (B) of the compressor (C).
Remove the belt (B) from the pulleys.
Place the new belt (B) on the pulleys.
Adjust the compressor belt tension according to the procedure shown in the previous paragraph.
Perform steps 3, 4, 5, 6 and 8 in the reverse order.
If necessary, fi ll the dust control system water tanks according to the procedure shown in the User Manual.
B
A
C
S301415
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.