Nilfisk-Advance America IVB 3-M Manuel D’Utilisation

Page de 18
13
english
IVB 3-M
IVB 5-M
IVB 7-M
1) 
Option depending on model
7. Check the antistatic clamp 
(5) for damage and have it 
replaced by Nilfisk Advance 
Service if necessary.
8. Check that the control flap 
(6) for filter cleaning works 
properly. The control flap 
should move back and for-
wards easily.
9.  Clean the level hose (7).
10. Fit a new filter element.
11. 
Fit the filter holder. Ensure 
that it is in the correct posi-
tion.
12. Fit bar and close bar handle.
13. 
Dispose of the used filter 
element in accordance with 
legal regulations.
Never use the vacuum cleaner 
without a filter.
1) 
Accessory. Order No. shown in section 9.5.
5
7
6
8 Troubleshooting
Fault
Cause
Remedy
‡ Motor does not start
> Fuse of the mains socket has 
blown.
Connect mains fuse.
> Overload protection switch 
has tripped.
Switch off the vacuum cleaner 
and allow it to cool for approx. 
5 minutes. If the cleaner can-
not be started again, contact 
the Nilfisk Advance service 
department.
> Self-acting carbon brush is 
worn.
Have carbon brushes changed 
by Nilfisk Advance Service.
‡ Motor does not run in auto-
matic mode
> Power tool is defective or not 
connected properly.
Check that the power tool 
works or that the plug is in-
serted correctly.
> The power rating of the elec-
trical tool is too low.
Note that minimum power rat-
ing is P>40W
‡ The acoustic warning 
sounds. (Reduced suction 
power)
> Suction power selected with 
suction power control is too 
low.
Set suction power in accord-
ance with section 4.2.3. „Set-
ting suction power“.
> Hose diameter and switch 
position do not correspond.
Set correct switch position for 
hose diameter.
> Clogged suction hose/nozzle.
Clean suction hose/nozzle
> Filter bag is full.
See section 7.2.2 „Replacing 
filter bag“.