warning
For safety reasons, an acoustic 
warning sounds if the air speed 
in the suction hose drops to be-
low 20 m/s. See section “Trou-
bleshooting”.
4.5 
Cleaning the filter 
element (IVB 3-M)
Only after picking up harmless dust 
using the waste bag.
If suction performance drops:
1. Set the suction power to 
maximum.
2.  Close the nozzles or suction 
hose opening with the palm 
of your hand.
3.  Press the button to start filter 
cleaning three times. The re-
sulting stream of air removes 
attached dust from the slats 
of the filter elements.
To ensure that suction perform-
ance is always at its best, the filter 
element is automatically cleaned 
during operation. We recommend 
complete cleaning if the filter ele-
ment becomes extremely dirty.
After picking up harmless dust us-
ing the waste bag.
If the acoustic signal sounds again 
after repeated cleaning, replace the 
filter element (see section 7.2.5).
4.6 
Cleaning the filter 
element (IVB 5-M/7-M)
1.  Switch off the vacuum clean-
er
2.  Close the nozzles or suction 
hose opening with the palm 
of your hand.
3.  Turn the switch to position „I“ 
and let the cleaner operate 
for approx. 10 seconds with 
the suction hose opening 
closed.
 
1
2
x3
Push & Clean
Filter Cleaning System
0
I
auto