What do I do, if ...
... it is difficult to push the nozzle
Reduce the power setting on the appliance. This
will not reduce cleaning efficiency.
... the motor thermal cut-out is activated
If  the  motor  is  overloaded,  e.g.  due  to  a  full
filter bag or blocked accessory, the thermal cut-
out shuts down the motor. In this case, switch
off the appliance, unplug from the mains, and
leave the motor to cool down.
Check paper filter bag, suction tube and suction
hose; remove any blockage.
The  appliance  can  be  switched  on  again  after
approximately 30 minutes.
... the fuse has blown
The  fuse  may  blow  if  you  use  other  electrical
appliances with high power consumption on the
same  electric  circuit  at  the  same  time  as  the
vacuum cleaner is in use.
This  can  be  avoided  if  you  set  the  electronic
power  adjuster  to  the  lowest  power  level  and
then  select  a  higher  level  after  switching  the
appliance on.
Your vacuum cleaner can be fitted with a gentle
startup  control  which  reduces  the  starting
current to the motor and therefore prevents the
electric  circuit  cut-out  being  triggered  under
normal conditions. It is possible that there will
be a delay of about 4 seconds in the appliance
starting up on the lowest power level.
... the paper filter is damaged at some point
and the motor protection filter becomes dirty
Remove  motor  protection  filter,  clean  (shake
out) and replace.
Insert new paper filter.
Special accessories
Turbo-brush
The turbo-brush makes the care of carpets and
hard  floors  easier.  The  rotary  motion,  of  its
brush  gently  loosens  shortpille  carpets  where
the dirt has been trodden in.
Special nozzle
For use on parquet tiled and, hard floors.