Emerson Series 3000 MVD Manuel D’Utilisation

Page de 348
Configuration and Use Manual
153
Operation Mode – Batch
Operation 
Mode
 –
 Ba
tc
h
T
o
tali
z
e
rs
 and
 In
ven
tories
Ope
ration 
Mode – Custod
y T
ra
n
s
fer
Op
eratio
n M
o
d
e
18.3.2
Cursor control buttons
The Lockout Target parameter can be set to allow the operator to change the target directly from the 
batch operation screen when the batch is not running (Lockout Target set to No). To enable target 
adjustment, see Section 11.5.
In Figure 18-4, the line beneath the farthest right digit of the target is the editing cursor. If Lockout 
Target is set to No, the cursor appears on the screen whenever the batch is not running. Whenever the 
cursor appears on the screen, you can use the cursor control buttons to change the target.
Figure 18-4 shows how the cursor control buttons work when the editing cursor is displayed.
Figure 18-4
Adjusting the batch target
18.4
Batch processing sequences
The following sequences (Figures 18-5 and 18-6) show the opening and closing of the primary and 
secondary valves, under normal processing and when 
STOP
 / 
RESUME
 is performed at different 
points during the batch. 
Note: Because the pump is on whenever a valve is open, it is not shown in these sequences.
For a description of two specific sequences, see the examples following the figures.
Increases value at cursor
Moves cursor right
Moves cursor left
Decreases value at cursor
Cursor
Note: If the petroleum measurement application or the enhanced density application is 
installed and the batch controller is measuring standard volume, net volume, or net mass, 
the actual and target values indicate net totals rather than gross totals.
DEVICE 1
Preset 1
Actual
0.0
kg
Target
12.3
START
HELP
VIEW