Emerson Model 1700 Manuel D’Utilisation

Page de 350
The default setting for Density Measurement Unit is g/cm3 (grams per cubic centimeter).
Options for Density Measurement Unit
The transmitter provides a standard set of measurement units for Density Measurement Unit.
Different communications tools may use different labels.
Options for Density Measurement Unit
Table 4-10:   
Unit description
Label
Display (stand-
ard)
Chinese-lan-
guage display
ProLink II
ProLink III
Field Commu-
nicator
Specific gravity unit (not
temperature-corrected)
SGU
SGU
SGU
SGU
SGU
Grams per cubic centime-
ter
G/CM3
g/cm3
g/cm3
g/cm3
g/Cucm
Grams per liter
G/L
g/L
g/l
g/l
g/L
Grams per milliliter
G/mL
g/mL
g/ml
g/ml
g/mL
Kilograms per liter
KG/L
kg/L
kg/l
kg/l
kg/L
Kilograms per cubic me-
ter
KG/M3
kg/m3
kg/m3
kg/m3
kg/Cum
Pounds per U.S. gallon
LB/GAL
lbs/US gal
lbs/Usgal
lbs/Usgal
lb/gal
Pounds per cubic foot
LB/CUF
lbs/ft3
lbs/ft3
lbs/ft3
lb/Cuft
Pounds per cubic inch
LB/CUI
lbs/in3
lbs/in3
lbs/in3
lb/CuIn
API gravity
D API
deg API
degAPI
degAPI
degAPI
Short ton per cubic yard
ST/CUY
sTon/yd3
sT/yd3
sT/yd3
STon/Cuyd
4.5.2
Configure slug flow parameters
Display (standard)
Not available
Chinese-language
display
Not available
ProLink II
ProLink
 > Configuration > Density > Slug High Limit
ProLink
 > Configuration > Density > Slug Low Limit
ProLink
 > Configuration > Density > Slug Duration
ProLink III
Device Tools
 > Configuration > Process Measurement > Density
Field Communicator
Configure
 > Manual Setup > Measurements > Density > Slug Low Limit
Configure
 > Manual Setup > Measurements > Density > Slug High Limit
Configure
 > Manual Setup > Measurements > Density > Slug Duration
Configure process measurement
Configuration and Use Manual 
45