Reference Manual
MAS2600: Ordering Information
Ed 21
December 2014
14
Forepeak Tank
If transducer measuring range > tank height: Select the next measuring range.
Example:
Tank height 12 m.
Based on the tank height a transducer with a measuring range of 16 mH
2
O should be selected.
However, due to the dynamic conditions in the forepeak tank, a transducer with a measuring range 
of 35 mH
2
O, i.e. the next in line, should be selected.
Turn amplifier range select switch to range No. 6.
Draft 
Transducer measuring range > max. draft minus sensor position.
This rule applies provided the transducer is mounted in accordance with the installation drawing for 
draft transmitters (vent pipe min. 1"). The sensor may be mounted directly on the sea valve with an 
air release valve depending on ship type and environment, always consult Marine Tank Management 
for proper installation guidance.