MAS2600: Intrinsically Safe Installation
Ed 21
December 2014
32
The entity concept allows inter-connections of intrinsically safe apparatus to associated apparatus 
not specifically examined in combination as a system. The approved values of maximum open circuit 
voltage and maximum short circuit current and maximum output power, for the associated appara-
tus must be less than or equal to the maximum safe input voltage (U
i
), maximum safe input current 
(I
i
), and maximum safe input power (P
i
) of the intrinsically safe apparatus. In addition, the approved 
maximum allowable connected capacitance of the associated apparatus must be greater than the 
sum of the inter-connecting cable capacitance and the unprotected internal capacitance (C
i
) of the 
intrinsically safe apparatus, and the approved maximum allowable connected inductance of the 
associated apparatus must be greater than the sum of the inter-connecting cable inductance and the 
unprotected internal inductance (L
i
) of the intrinsically safe apparatus.
Grounding