Emerson 2700 Manuel D’Utilisation
![Emerson](https://files.manualsbrain.com/attachments/1ef3aaad462e024fde6cecf537a4c6c781334d44/common/fit/150/50/6dab323528eefa0342baa74a10c15551c3b956250cf9d62f2117dcdf42a7/brand_logo.jpeg)
58
Micro Motion
®
Model 1700 and 2700 Transmitters
Specifications
One frequency/pulse output (Model 1700 transmitters) or frequency/pulse/discrete output (Model
2700 transmitters):
2700 transmitters):
•
Intrinsically safe
•
Externally powered (passive)
•
Maximum input voltage: 30 VDC, 0.75 watt maximum
•
Frequency/pulse output (Model 1700/2700):
-
Can be used to indicate either flow rate or total; Model 1700 output reports the same flow
variable as the mA output, Model 2700 output is independent from mA output
variable as the mA output, Model 2700 output is independent from mA output
-
Scalable to 10,000 Hz
-
Linear with flow rate to 12,500 Hz
-
Configurable polarity: active high or active low
-
Maximum load limit: see following chart
0
100
200
300
400
500
600
700
800
900
1000
12
14
16
18
20
22
24
26
28
30
mA Output Load Resistance Value
R
max
= (V
supply
- 12)/0.023*
*If communicating with HART a minimum of 250 Ohms
and 17.75 V supply is needed
Supply voltage (volts)
Exter
nal resistor
(Ohm
s)
Operating
Region
Region