Emerson MMI-20016185 Manuel D’Utilisation

Page de 44
Wiring the 9739 MVD transmitter to the sensor
Micro Motion 9-wire cable types and usage
Cable types
Micro Motion supplies three types of 9-wire cable: jacketed, shielded, and armored. Note the following differences
between the cable types:
• Armored cable provides mechanical protection for the cable wires.
• Jacketed cable has a smaller bend radius than shielded or armored cable.
• If ATEX compliance is required, the different cable types have different installation requirements.
Cable jacket types
All cable types can be ordered with a PVC jacket or Teflon
®
FEP jacket. Teflon FEP is required for the following installation
types:
• All installations that include a T-series sensor.
• All installations with a cable length of 250 ft (75 m) or greater, a nominal flow less than 20 percent, and ambient
temperature changes greater than +68 °F (+20 °C).
Table 4-4 shows the temperature ranges of the cable jacket materials.
Table 4-4
Cable jacket material and temperature ranges
Handling temperature
Operating temperature
Cable jacket material
Low limit
High limit
Low limit
High limit
PVC
–4 °F (–20 °C)
+194 °F (+90 °C)
–40 °F (–40 °C)
+221 °F (+105 °C)
Teflon FEP
–40 °F (–40 °C)
+194 °F (+90 °C)
–76 °F (–60 °C)
+302 °F (+150 °C)
Cable bend radii
The following tables show the cable bend radii of the different cables and the jacket materials:
• Table 4-5 shows the bend radii of jacketed cable.
• Table 4-6 shows the bend radii of shielded cable.
• Table 4-7 shows the bend radii of armored cable.
Table 4-5
Bend radii of jacketed cable
Minimum bend radii
Jacket material
Outside diameter
Static (no load) condition
Under dynamic load
PVC
0.415 inches (10 mm)
3–1/8 inches (80 mm)
6–1/4 inches (159 mm)
Teflon FEP
0.340 inches (9 mm)
2–5/8 inches (67 mm)
5–1/8 inches (131 mm)
20