Emerson 1700 Manuel D’Utilisation

Page de 80
42
Micro Motion
®
 Model 1700 and 2700 Transmitters
Output Wiring – Model 2700 Configurable I/O Transmitters
Figure 6-1
Configuration of configurable I/O terminals
6.3
mA output wiring
The following 4–20 mA wiring diagrams are examples of proper basic wiring for the Model 2700 
primary and secondary mA outputs. The following options are shown:
HART/analog single-loop wiring (Figure 6-3)
Note: If you will configure the transmitter to poll an external temperature or pressure device, you 
must wire the mA output to support HART communications. You may use either HART/analog 
single-loop wiring or HART multidrop wiring.
Table 6-1
Channel configuration
Channel
Terminals
Configuration options
Power
A
1 & 2
mA output with HART/Bell 202
(1)
(1) The Bell 202 signal is superimposed on the mA output.
Internal
B
3 & 4
• mA output (default)
Internal
• Frequency output
Internal or external
(2)
(2) You must provide power to the outputs when a channel is set to external power.
• Discrete output
Internal or external
C
5 & 6
• Frequency output (default)
(3)
(3) When configured for two frequency outputs (dual pulse), frequency output 2 is generated from the same signal that is sent 
to the first frequency output. Frequency output 2 is electrically isolated but not independent.
Internal or external
• Discrete output
Internal or external
• Discrete input
Internal or external
Terminals 1 and 2 (Channel A)
mA1 output
Internal power only
HART (Bell 202) communications
Terminals 3 and 4 (Channel B)
mA2 output or FO or DO1
Power: 
•  mA – internal only
•  FO or DO – internal or external
No communications
Terminals 5 and 6 (Channel C)
FO or DO2 or DI
Power: internal or external
No communications
mA = milliamp
FO = frequency output
DO = discrete output
DI = discrete input
+
+
+