Emerson IFT9701 Manuel D’Utilisation

Page de 90
Model IFT9701 Transmitter Instruction Manual
19
Ge
tti
n
g
 Sta
rted
P
o
wer
 Su
pp
ly
 an
d O
u
tp
ut Wi
ri
ng
Mounting the 
Remo
te T
ransmitter
Be
fo
re
 Y
o
Begin
Chapter 4
Power Supply and Output Wiring
4.1
Overview
To wire the transmitter power supply and outputs:
Review the wiring guidelines (see Section 4.2)
Connect the power supply wiring (see Section 4.3)
Connect the output wiring (see Section 4.4)
4.2
Wiring guidelines
Install cable and wiring so they meet local code requirements.
The transmitter has two separate ¾-inch NPT or M20 female conduit openings, which must 
remain sealed to keep the transmitter watertight. See Figure 4-1 and Figure 4-2.
The transmitter has a sensor wiring compartment for intrinsically safe sensor wiring, and a 
field wiring compartment for non-intrinsically safe power supply and output wiring. See 
Figure 4-1 and Figure 4-2.
-
For power supply and output wiring, loosen the four captive screws that secure the cover 
of the field wiring compartment.
-
Access to the sensor wiring and circuit board compartments is not required for power 
supply and output wiring.