State Industries 740A Manuel D’Utilisation

Page de 37
3
are different from natural gas models.  A natural gas heater 
will not function safely on LP gas and no attempt should be 
made to convert a heater from natural gas to LP gas.
GPG/GPV-540A, 650A & 740A models are not available for use 
with liquefied Petroleum or lP gas.  If you have obtained a  
GPG/GPV-540A, 650A or 740A model with the intent to use it  
with liquefied Petroleum, lP gas - stoP! Immediately contact 
your dealer to obtain a correct model.
CHEMiCAL VAPOr COrrOSiON
  wArNiNG
COrrOSiON OF THE FLUEwAyS AND VENT SySTEM MAy 
OCCUr  iF Air  FOr  COMBUSTiON  CONTAiNS  CErTAiN 
CHEMiCAL VAPOrS.  SUCH COrrOSiON MAy rESULT iN 
FAiLUrE AND riSk OF ASPHyXiATiON.
Spray  can  propellants,  cleaning  solvents,  refrigerator  and  air 
conditioning  refrigerants,  swimming  pool  chemicals,  calcium 
GENErAL SAFETy iNFOrMATiON
PrECAUTiONS
DO  NOT  USE  THIS APPLIANCE  IF ANY  PART  HAS  BEEN 
UNDER WATER.  Immediately call a qualified service technician 
to inspect the appliance and to replace any part of the control 
system and any gas control which has been under water.
IF THE  UNIT  IS  EXPOSED TO THE  FOLLOWING,  DO  NOT 
OPERATE  HEATER  UNTIL ALL  CORRECTIVE  STEPS  HAVE 
BEEN MADE BY A QUALIFIED SERVICEMAN.
1.  EXTERNAL FIRE.
2.  DAMAGE.
3.  FIRING WITHOUT WATER.
4.  SOOTING.
LiQUiD PETrOLEUM MODELS
  wArNiNG
Water heaters for propane or liquefied petroleum gas (lPG) 
TABLE OF CONTENTS
ROUGH-IN-DIMENSIONS ....................................................................2
FOREWORD ......................................................................................2,3
TABLE OF CONTENTS .........................................................................3
GENERAL SAFETY INFORMATION .....................................................3
 
Precautions ...................................................................................3
 
Liquid Petroleum Models ...............................................................3 
 
Chemical Vapor Corrosion..........................................................3,4
 
Improper Combustion ....................................................................4
EXTENDED NON-USE PERIODS ........................................................4
 
Cathodic Protection .......................................................................4
 
Insulation Blankets ........................................................................4
 
High Altitude Installations ..............................................................4
FEATURES ............................................................................................4
 
Low Emmission Control .................................................................4
 
High Limit Switch (E.C.O.) ..........................................................4,5
 
Dishwashing Machine Requirement ..............................................5
INSTALLATION INSTRUCTIONS .........................................................5
 
Required Ability .............................................................................5
 
Uncrating .......................................................................................5
 
Locating the Heater ....................................................................5,6
 
Hard Water ....................................................................................6
 
Clearances ....................................................................................6
 
Air Requirements ...........................................................................6
 
Venting .......................................................................................6,7
 
Vertical Venting - For GPG Models ...............................................7
 
Horizontal (Side-wall) Venting - For GPV Models ......................7,8
 
Direct Venting - For GPV Models .............................................9-11
 
Gas Piping ..............................................................................11-12
 
Gas Meter Size ............................................................................12
 
Gas Pressure Regulation ............................................................12
 
Gas Valves .............................................................................12,13
 
Water Line Connections ..............................................................13
 
Thermometers .............................................................................13
 
Relief Valve.................................................................... .............13
INSTALLATION DIAGRAMS ..........................................................14-17
 
Manifold Kits ................................................................................18
 
Heater Wiring ..............................................................................19
START UP ...........................................................................................19
 
Important .....................................................................................19
 
Filling ...........................................................................................19
 
Purging ........................................................................................19
 
Wiring Diagram .......................................................................20,21
 
Lighting and Operating Label ......................................................22
 
Sequence of Operation ...............................................................23
 
Water Temperature Control .........................................................23
 
Adjustment Procedure (Initial Start-Up) ..................................23,24
 
Adjustment Procedure for Fire-Rate, Low Nox and
 
High Elevation (Fine-Tune) .....................................................24-26
GENERAL INFORMATION ..................................................................27
 
Power Burner ..............................................................................27
 
Thermostat ..................................................................................27
 
High Limit ....................................................................................27
MAINTENANCE ..................................................................................27
 
General ........................................................................................27
 
Maintenance Schedule ................................................................27
 
Electrical Servicing ......................................................................27
 
Flushing .......................................................................................27
 
Draining .......................................................................................28
 
Sediment Removal ......................................................................28
 
Lime Scale ...................................................................................28
 
Relief Valve.............................................................................28,29
 
Circulating Pump .........................................................................29
 
Low Emission Power Burner .......................................................29
 
Cleaning Flues ............................................................................29
 
Barometric Draft Control ..............................................................29
 
Vent System ................................................................................29
CHECKLIST AND SERVICE INFORMATION ................................29-30
TROUBLESHOOTING ...................................................................30-32
 
Replacement Parts ......................................................................32
WARRANTY  .......................................................................................33
PARTS LIST ...................................................................................34-39
PAGE
PAGE
In addition to these instructions, the equipment shall be installed 
in accordance with those installation regulations in accordance 
with those installation regulations in force in the local area where 
the installation is to be made.  These shall be carefully followed 
in all cases.  Authorities having jurisdiction should be consulted 
before installations are made.
In the absence of local codes, the installation must conform with 
the instructions as outlined in the latest publication of  National Fuel 
Gas Code (NFPA-54/ANSI Z223.1) and  National Electric Code 
(NFPA-70).  These manuals can be purchased from the Canadian 
Standards Association Laboratories, 8501 East Pleasant Valley 
Road, Cleveland, OH  44131, National Fire Protection Association, 
1 Batterymarch Park, Quincy MA 02269.