State Industries CSB 82 Fascicule
COMMERCIAL
For more information on this product contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024 Toll-free USA
www.statewaterheaters.com
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024 Toll-free USA
www.statewaterheaters.com
SOLID.STATE.
SCESS00508
SUGGESTED SPECIFICATION
The heater(s) shall be SandBlaster CSB Series Commercial Electric Model Number ______________ as manufactured by State Industries shall be rated at
____________kW,_______volts, ____________ phase, 60 cycle AC, and listed by Underwriters’ Laboratories and approved to the NSF Standard 5 by UL. Tank(s) shall be
________ gallon capacity. Tanks shall be 50, 80 and 119 gallon capacity and shall have 150 psi working pressure and be equipped with extruded high density anode.
All internal surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition that has been fused-to-steel by firing at a temperature range
of 1400°F to 1600°F. Electric heating elements shall be gold plated low watt density screw-in type. Each element shall be controlled by an individually mounted thermostat and high temperature
cut-off switch. All internal circuits shall be fused. The outer jacket shall be of baked enamel finish and shall be provided with full size control compartment for performance of service and maintenance
through hinged front panel and shall enclose the tank with foam insulation. Electrical junction box with heavy duty terminal block shall be provided. The drain valve shall be located in the front for ease
of servicing. Heater tank shall have a three year limited warranty as outlined in the written warranty. Manufacturer shall supply ASME rated temperature and pressure relief valve. Fully illustrated
instruction manual to be included. Meets ASHRAE 90.1b -1992 and ASHRAE/IESNA 90.1-2004.
____________kW,_______volts, ____________ phase, 60 cycle AC, and listed by Underwriters’ Laboratories and approved to the NSF Standard 5 by UL. Tank(s) shall be
________ gallon capacity. Tanks shall be 50, 80 and 119 gallon capacity and shall have 150 psi working pressure and be equipped with extruded high density anode.
All internal surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition that has been fused-to-steel by firing at a temperature range
of 1400°F to 1600°F. Electric heating elements shall be gold plated low watt density screw-in type. Each element shall be controlled by an individually mounted thermostat and high temperature
cut-off switch. All internal circuits shall be fused. The outer jacket shall be of baked enamel finish and shall be provided with full size control compartment for performance of service and maintenance
through hinged front panel and shall enclose the tank with foam insulation. Electrical junction box with heavy duty terminal block shall be provided. The drain valve shall be located in the front for ease
of servicing. Heater tank shall have a three year limited warranty as outlined in the written warranty. Manufacturer shall supply ASME rated temperature and pressure relief valve. Fully illustrated
instruction manual to be included. Meets ASHRAE 90.1b -1992 and ASHRAE/IESNA 90.1-2004.
Figured at 1 kW (3413 BTU) = 4.1 Gallons at 100°F temperature rise.
RECOVERY RATE IN GALLONS PER HOUR AT TEMPERATURE RISE OF
Standard
kW Input
kW Input
BTU/ Hour
3O°F
17°C
40°F
22°C
5O°F
28°C
60°F
33°C
70°F
39°C
8O°F
45°C
9O°F
50°C
100°F
56°C
110°F
61°C
120°F
67°C
130°F
72°C
140°F
78°C
6
20,478
82
310
62
233
49
166
41
155
35
133
31
116
27
103
25
93
93
22
85
85
21
78
78
19
72
72
18
66
66
9
30,717
123
465
465
92
349
74
279
62
233
53
199
46
174
41
155
37
140
34
127
31
116
28
107
26
100
12
40,956
164
620
620
123
465
465
98
372
82
310
70
266
61
233
55
207
49
186
45
169
41
155
38
143
35
133
13.5
46,075
184
698
698
138
523
523
111
419
419
92
349
79
299
69
262
62
233
55
209
50
190
46
174
43
161
40
150
15
51,195
205
775
775
154
582
582
123
465
465
102
388
388
88
332
77
291
68
258
61
233
56
211
51
194
47
149
44
166
18
61,434
246
930
930
184
698
698
148
558
558
123
465
465
105
399
399
92
349
82
310
74
279
67
254
62
233
57
215
53
199
24
81,912
328
1241
246
930
930
197
744
744
164
620
620
140
532
532
123
465
465
109
414
414
98
372
90
338
82
310
76
286
70
266
27
92,151
369
1396
276
1047
221
938
938
185
609
609
158
509
509
138
523
523
123
465
465
111
410
410
101
391
391
92
340
85
322
79
299
30
102,390
410
1551
307
1163
246
930
930
205
775
775
176
665
665
154
582
582
137
517
517
123
465
465
112
423
423
102
388
388
95
358
88
332
36
122,868
492
1861
369
1396
295
1117
246
930
930
211
798
798
184
698
698
164
620
620
148
556
556
134
508
508
123
465
465
113
429
429
105
399
399
40.5
138,226
554
2094
418
1570
332
1256
277
1047
237
897
897
208
785
785
185
698
698
166
628
628
151
634
634
138
582
582
128
537
537
119
498
498
45
153,585
615
2326
461
1745
369
1398
307
1163
263
997
997
230
872
872
205
755
755
184
698
698
168
634
634
154
582
582
142
537
537
132
498
498
54
184,302
738
2791
554
2094
443
1675
359
1396
316
1196
277
1047
246
930
930
221
837
837
201
761
761
185
696
696
170
644
644
158
598
598
Model
Number
Tank
Capacity
Dimensions
Inlet/
Outlet (NPT)
Approx. Ship.
Wt. (Lbs.)
A
B
C
gal. litre
in.
cm
in.
cm
in.
cm
in.
cm
Ib
kg
CSB 52**SFE
50
189
55 3/4
142
21 3/4
55.2
27
68.6
1 1/4
3.2
265
120
CSB 82**SFE
80
300
60 1/4
153
25 1/2
64.8
31
78.7
1 1/4
3.2
280
127
CSB 120**SFE 119
450
62 1/4
158.1
29 1/2
75.0
35
88.9
1 1/4
3.2
390
177
*208 volt models may contain three (3) additional elements. ** Elements available in incoloy only.
kW
Input
Model Numbers
Tank Capacity in Gallons
Number
Of
Elements
Element
Wattage
Full Load Current In Amperes
Single Phase
Three Phase
50
80
119
208V
240V
277V
480V
208V
240V
480V
6
CSB 52 6 SFE
CSB 82 6 SFE
CSB 120 6 SFE
3
2,000
28.8
25.0
21.7
12.5
16.7
14.4
7.2
9
CSB 52 9 SFE
CSB 82 9 SFE
CSB 120 9 SFE
3
3,000
43.3
37.5
**32.5
18.8
25.0
21.7
10.8
12
CSB 52 12 SFE
CSB 82 12 SFE
CSB 120 12 SFE
3
4,000
57.7
50.0
43.3
25.0
33.3
28.9
14.4
13.5
CSB 52 135 SFE
CSB 82 135 SFE
CSB 120 135 SFE
3
4,500
64.9
56.3
**48.7
28.1
37.5
32.5
16.2
15
CSB 52 15 SFE
CSB 82 15 SFE
CSB 120 15 SFE
3
5,000
72.1
62.5
**54.2
31.3
41.6
36.1
18.0
18
CSB 52 18 SFE
CSB 82 18 SFE
CSB 120 18 SFE
3*
6,000
86.5
75.0
65.0
37.5
50.0
43.3
21.7
24
CSB 52 24 SFE
CSB 82 24 SFE
CSB 120 24 SFE
6
4,000
115.4
100.0
86.6
50.0
66.6
57.7
28.9
27
CSB 52 27 SFE
CSB 82 27 SFE
CSB 120 27 SFE
6
4,500
129.8
112.5
**97.5
56.3
74.9
65.0
32.5
30
CSB 52 30 SFE
CSB 82 30 SFE
CSB 120 30 SFE
6
5,000
144.2
125.0
**108.3
62.5
83.3
72.2
36.1
36
CSB 52 36 SFE
CSB 82 36 SFE
CSB 120 36 SFE
6*
6,000
173.1
150.0
130.0
75.0
99.9
86.6
43.3
40.5
N/A
CSB 82 405 SFE
CSB 120 405 SFE
9
4,500
194.7
168.8
**146.2
84.4
112.4
97.4
48.7
45
N/A
CSB 82 45 SFE
CSB 120 45 SFE
9
5,000
216.3
187.5
**162.5
93.8
124.9
108.3
54.1
54
N/A
CSB 82 54 SFE
CSB 120 54 SFE
9
6,000
N/A
225.0
194.9
112.5
149.9
129.9
65.0
2010R
September