Rinnai R75LSI (VA2528FFUD) Fascicule

Page de 2
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
0
25
50
75
100
125
150
delta T - Temperature Rise (ºF) 
 Water Flo
w
 (gpm)
 
R75LSi (VA2528FFUD)    
Type of Appliance 
Rinnai Model Number 
Operation / Exhaust System  
Minimum/Maximum Gas Rate (Input) 
Electrical 
 
Electrical Consumption 
 
 
Ignition System 
Hot Water Capacity 
Temperature 
 
 
Temperature (without remote)  
Approved Gas Types 
Installation 
Energy Factor 
Thermal Efficiency 
Service Connections 
 
 
Water Flow Control 
Minimum/Maximum Water Supply Pressure 
Temperature controlled, continuous flow, gas hot water system 
REU-VA2528FFUD(A)-UC 
Forced combustion / Direct vent 
15,000 - 180,000 BTU/h (Natural Gas and Propane)  
Appliance: 
 
 
AC 120 Volts - 60 Hz 
Controller: 
  DC 
12 
Volts 
Normal 
   65 
watts 
Standby   2.0 
watts 
Anti-frost protection 
 
100 watts 
Direct electronic ignition 
0.6 to 7.5 GPM (35° F rise) 
98° - 120° F  (factory default)  Maximum temperature is selectable at 
120° F or at 140° F;  98° - 160° F available with the MCC-91 
controller for commercial and hydronic applications 
120° F (factory default) 
Natural or Propane (ensure unit matches gas type) 
Indoor only 
Natural Gas: 0.82 
 
Propane: 0.82 
Natural Gas: 84% 
 
Propane: 84% 
Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 
Water flow sensor, electronic water control device and fixed by-pass 
20 - 150 PSI (recommended 30-80 PSI for maximum performance) 
© 2008 Rinnai Corporation 
R75LSi SP                         8/2008 
FLOW TABLE