Rinnai Infinity 32e Manuel D’Utilisation

Page de 40
15 
TEMPERATURE CONTROLS - GENERAL 
When deciding on the best position for the temperature controls, the following points 
should be taken into account. 
 
Fit the controls out of reach of children (suggested height from the floor 1.5m.) 
 
Avoid positions where the controllers will become hot.  Do not fit them near stoves or 
ovens, or above radiators or heaters. 
 
If possible, avoid exposure to direct sunlight or positions where bright lights will make 
the digital display difficult to read. 
 
Position away from areas where the controller will be prone to splashing by cooking 
products such as oils and fats. 
 
The temperature controllers are water resistant, however they should be positioned 
away from areas where direct or persistent splashing could occur. 
 
Refer to the I.E.E electrical wiring regulations current edition for location requirements 
in shower and bath areas. 
 
The cables to the temperature controller carry only 12VDC (extra low voltage.) 
 
When using more than one temperature controller the signal cable should be run in 
parallel.  That is, from controller to controller to heater, or from each controller to the 
heater.  Do not wire the controllers in series. 
 
The installation in every application will vary, therefore the temperature controller cable 
has been provided so that you may cut the length accordingly and fit the spade 
connectors, ensuring a good connection. 
 
Cables are simply ‘piggy-backed’ at the water heater or at the primary temperature 
controller. Polarity is not important when connecting the cables, either colour wire can 
be connected to either terminal at both the heater or primary temperature controller. If 
more cable is needed any cable with similar specification to the cable supplied with the 
controller can be used. Maximum length is 50 metres.