DIAGNOSTIC POINTS
Diagnostic Points- To be read in conjunction with the wiring diagram.
COMPONENT
SURGE PROTECTOR
WATER FLOW
CONTROL DEVICE
CONTROL DEVICE
BY-PASS FLOW
CONTROL DEVICE
CONTROL DEVICE
REMOTE CONTROL
WATER FLOW SENSOR
COMBUSTION FAN
FLAME ROD
MODULATING VALVE
OUTGOING THERMISTOR
HEAT EXCHANGER
OUTGOING THERMISTOR
HEAT EXCHANGER
OUTGOING THERMISTOR
THERMAL FUSE
IGNITER
MAIN SOLENOID VALVE
SOLENOID VALVE 1
SOLENOID VALVE 2
SOLENOID VALVE 3
B-Br
R-B
Gy-Or
Gy-Y
Gy-Br
Br-W
Or-W
Y-W
R-W
GND
Bk-Bk
R-Bk
Y-Bk
GND
W-Bk
GND
CHECK TERMINAL
Y-BODY EARTH
Or-Or
W-W
R-R
Gy-Bk
P-Bk
R-Bk
Or-Bk
Y-Bk
1
2
16
3
4
5
6
7
8
9
10
11
12
13
14
15
A NOTE
OPERATE ELECTRICITY
CONTROL ELECTRICITY
FULL OPEN POSITION
FULL CLOSE POSITION
OPERATE CONDITION
ON2.4L/min〔33Hz〕
OVER 1800PULSE/MIN
OFF1.7L/min〔23Hz〕
BELOW 1200PULSE/min
NO FLAME CONDITION
FLAME CONDITION
NORMAL VALUE
AC207∼264V
DC11∼13V
DC11∼13V
DC11∼13V
BELOW DC1V〔LIMITER ON〕
DC4∼6V〔LIMITER OFF〕
BELOW DC1V〔LIMITER ON〕
DC4∼6V〔LIMITER OFF〕
DC2∼6V
15∼35Ω
DC11∼13V
DC11∼13V
DC4∼7V〔PULSE 17∼460Hz〕
DC2∼9V
60∼360Hz
AC100∼160V
OVER DC1μA
AC1.0∼25V
70∼90Ω
15℃…11.4∼14.0kΩ
30℃…6.4∼7.8kΩ
45℃…3.6∼4.5kΩ
60℃…2.2∼2.7kΩ
105℃…0.6∼0.8kΩ
BELOW 1Ω
AC90∼110V
DC80∼100V
1.5∼1.9kΩ
DC80∼100V
1.8∼2.2kΩ
DC80∼100V
1.8∼2.2kΩ
DC80∼100V
1.8∼2.2kΩ
J
7
B
2
B
1
H
1
E
3
C
A
1
F
3
E
1
E
2
F
1
J
6
I
1
I
2
I
3
I
4
FLOW
CHART
NO.
MEASUREMENT POINT
CN
WIRE COLOR
TRANSFORMER
VOLTAGES AND
RESISTANCE
CN
A
2
D
A
A
WIRE COLOR
R-R
Gr-Gr
Br-Gy
Y-Gy
NORMAL VALUE
AC90∼110V
12∼21Ω
AC12∼18V
2.4∼4.3Ω
AC30∼50V
2.2∼3.9Ω
AC180∼220V
300∼530Ω