Reliance Water Heaters N71120NE Manuel D’Utilisation

Page de 56
27
checking the input
for appliance installation locations with elevations above 2000 
feet, refer to HIgH ALTITuDe INSTALLATIoNS section of this 
manual for input reduction procedure.
1.  Attach  a  pressure  gauge  or  a  manometer  to  the  manifold 
pressure tap on the gas valve and  refer to Table 10, for correct 
manifold pressure.
2.  use this formula to “clock” the meter.  Be sure that other gas 
consuming appliances are not operating during this interval.
  (3600/T) x H = Btuh
  T  =  Time in seconds to burn one cubic foot of gas.
  H = Btu’s per cubic foot of gas.
  Btuh = Actual heater input.
  example: (using N100 250Ne heater)
  T  =  15.1 seconds
  H  =  1050 Btu
  Btuh  =  ?
  (3600/15.1) x 1050 = 250,000 (Compare with N100 250Ne 
model and rating.)
Should  it  be  necessary  to  adjust  the  gas  pressure  to  the 
burners to obtain the full input rate, the steps below should 
be followed:
3.  remove the regulator adjustment sealing cap and adjust the 
pressure by turning the adjusting screw with a screwdriver. See 
figure 25.
 
 Clockwise to increase gas pressure and input rate.
 
 Counterclockwise to decrease gas pressure and input rate.
4. “Clock” the meter as in step 2 above.
5. repeat steps 3 and 4 until the specified input rate is achieved.
6. Turn the gas control knob to PILoT.  remove the pressure 
gauge and replace the sealing cap and the Allen wrench set 
screw in the pressure tap opening.
uNDer No CIrCumSTANCeS SHouLD THe gAS INPuT eXCeeD 
THe  INPuT  SHoWN  oN  THe  HeATer  moDeL  AND  rATINg 
PLATe.  oVerfIrINg  CouLD  reSuLT  IN  DAmAge  or  SooTINg 
of  THe  HeATer.