Rinnai R98EASME Fascicule

Page de 2
R98eASME (V3237W-ASME)  
Type of Appliance 
Rinnai model number 
Operation  
Minimum/Maximum Gas Rate (Input) 
Electrical 
 
Electrical Consumption 
 
 
Ignition System 
Hot Water Capacity 
Temperature 
Temperature (without controller)  
Approved Gas Types 
Installation 
Thermal Efficiency 
Service Connections 
 
 
Water Flow Control 
Minimum/Maximum Water Supply Pressure 
Temperature controlled, continuous flow, gas hot water system 
REU-V3237W-ASME 
Forced combustion 
19,000 - 237,000 BTU/h (Natural Gas or Propane) 
Appliance: 
 
 
AC 120 Volts - 60 Hz 
Controller: 
  DC 
12 
Volts 
Normal 
   72 
watts 
Standby   2 
watts 
Anti-frost protection 
 
116 watts 
Direct electronic ignition 
0.6 to 8.0 GPM (50° F rise) 
0.9 to 9.8 GPM (35° F rise) 
98° - 140° F  
120° F (factory default) 
Natural or Propane (ensure unit matches gas type) 
Outdoor only 
Natural Gas: 85% 
 
Propane: 83% 
Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 
Water flow sensor, electronic water control and by-pass control  
15 - 150 PSI (50 PSI or above is recommended for maximum flow) 
© 2008 Rinnai Corporation 
3237W-ASME SP-1                       4/2008 
FLOW TABLE 
Water Flow Capacity Curve 
 
R
This model has been built in accordance with the requirements of 
the ASME Boiler and Pressure Vessel Code and has received the 
Certificate of Authorization from the National Board.  The heat 
exchanger has the NB and the HLW stamps.