Rinnai REU-VB2528WD-US Fascicule

Page de 2
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
0
25
50
75
100
125
150
delta T - Temperature Rise (ºF) 
 Water Flo
w
 (gpm)
 
RL75e (VB2528WD-US)    
Type of Appliance 
 
 
 
Rinnai Model Number 
Minimum/Maximum Gas Rate (Input) 
 
Electrical 
 
Electrical Consumption 
Ignition System 
Hot Water Capacity 
 
 
Temperature 
 
 
Temperature (without remote)  
Installation 
Energy Factor 
Service Connections 
 
Isolation & Pressure Relief Valves Included 
 
Water Flow Control 
Minimum/Maximum Water Supply Pressure 
•  Temperature controlled, continuous flow, gas hot water system 
•  Certified for installation in manufactured (mobile) homes 
•  Forced combustion 
•  Energy Star qualified 
REU-VB2528WD-US 
9,900 - 180,000 BTU/h (Natural Gas)  
10,300 - 180,000 BTU/h (Propane)  
Appliance: 
 
 
AC 120 Volts - 60 Hz 
Controller: 
  DC 
12 
Volts 
Normal:  44 w  Standby:  2 w  Anti-frost protection:  104 w 
Direct electronic ignition 
Minimum flow rate: 0.26 GPM 
Minimum activation flow rate: 0.4 GPM 
Maximum flow rate: 7.5 GPM 
98° - 120° F  (factory default)  Maximum temperature is selectable at 
120° F or at 140° F;  98° - 160° F available with the MCC-91 
controller for commercial and hydronic applications 
120° F (factory default) or 140° F 
Outdoor only 
Natural Gas: 0.82 
 
Propane: 0.82 
Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 
Heavy duty forged brass Webstone Isolator valves EXP E2, certified 
to NSF/ANSI 61-8 for potable water 
Water flow sensor, electronic water control device and fixed by-pass 
20 - 150 PSI (recommended 30-80 PSI for maximum performance) 
© 2011 Rinnai Corporation 
RL75e VB SP                           1/2011 
FLOW TABLE