Rinnai REU-VB2735WD-US Fascicule

Page de 2
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
0
25
50
75
100
125
150
T – Temperature Rise (°F)
H
o
W
at
er
 Fl
ow
 R
at
e (
gpm
)
R94LSe (VB2735WD-US)    
Type of Appliance 
 
Rinnai Model Number 
Operation 
Minimum/Maximum Gas Rate (Input) 
 
Electrical 
 
Electrical Consumption 
 
 
Ignition System 
Hot Water Capacity 
 
 
Temperature 
 
 
Temperature (without remote)  
Approved Gas Types 
Installation 
Energy Factor 
Thermal Efficiency 
Service Connections 
 
Water Flow Control 
Minimum/Maximum Water Supply Pressure 
Temperature controlled, continuous flow, gas hot water system; 
certified for installation in manufactured (mobile) homes 
REU-VB2735WD-US 
Forced combustion 
9,900 - 199,000 BTU/h (Natural Gas)  
10,300 - 199,000 BTU/h (Propane)  
Appliance: 
 
 
AC 120 Volts - 60 Hz 
Controller: 
  DC 
12 
Volts 
Normal 
   49 
watts 
Standby   2 
watts 
Anti-frost protection 
 
104 watts 
Direct electronic ignition 
Minimum flow rate: 0.26 GPM 
Minimum activation flow rate: 0.4 GPM 
Maximum flow rate: 9.4 GPM (35° F rise) 
98° - 120° F  (factory default)  Maximum temperature is selectable at 
120° F or at 140° F;  98° - 185° F available with the MCC-91 
controller for commercial and hydronic applications 
120° F (factory default) 
Natural or Propane (ensure unit matches gas type) 
Outdoor only 
Natural Gas: 0.82 
 
Propane: 0.82 
Natural Gas: 83% 
 
Propane: 83% 
Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 
Water flow sensor, electronic water control device and fixed by-pass 
20 - 150 PSI (recommended 30-80 PSI for maximum performance) 
© 2010 Rinnai Corporation 
R94LSe VB SP                           8/2010 
FLOW TABLE