DIAGNOSTICS FOR HONEYWELL CONTROL 
 
LED Status 
Control Status 
Probable Cause 
None (LED not on or 
flashing) 
Millivolt power is not 
present. Light pilot. 
1.  Gas valve is functioning 
normally 
2.  Gas valve is not powered. 
Light pilot 
One flash and three 
second pause. 
If set point knob is in 
"PILOT" position then pilot 
flame is detected. 
(no 
faults).
 
Gas valve is powered and waiting 
for the set point knob to be turned 
to a water temperature setting. If 
the set point knob is at desired 
setting the thermostat is satisfied. 
LED strobe (two quick 
flashes) and three second 
pause 
Thermostat calling for heat 
(no faults)
 
Water heater operating normally. 
LED on continuously. 
Set point knob has been 
recently turned to the 
"OFF" position.  
Set point knob was recently turned 
to "OFF" position.  Wait until LED 
goes out before attempting to 
relight 
Two flashes and three 
second pause. 
Weak pilot flame detected. 
System will reset when 
pilot flame is sufficient.  
1.  Unstable pilot.  
2.  Pilot tube blocked or 
restricted.  
Three flashes and three 
second pause. 
Insufficient water heating. 
System will reset.  
1.  Temperature sensor out of 
calibration.  
2. Possible 
short. 
Four flashes and three 
second pause. 
Excessive tank 
temperature. System must 
be reset.  
1.  Temperature sensor out of 
calibration.  
2.  Faulty gas valve. 
Five flashes and three 
second pause. 
Temperature sensor fault. 
1.  Damage to the temperature 
wire. 
2. Temperature 
sensor 
resistance out of range.  
3.  Replace temperature sensor.  
4.  If temperature sensor 
replacement does not correct 
the problem; Verify control is 
not wet or physically damaged 
5.  Turn set point knob to "OFF" 
position. Turn set point knob 
to "PILOT" position and light 
pilot.                                         
6.  Replace gas valve if five flash 