Remove the Old Thermostat
1.  Turn off power to the heating and cooling system.
2.  Remove the front cover of the old thermostat, this usually 
pulls off.
3.  Loosen the screws that hold the thermostat to the wall.
4.  Identify each wire attached to the old thermostat.
5.  Disconnect the wires from old thermostat one at a time. 
DO 
NOT LET WIRES FALL BACK INTO THE WALL.
Install the New Thermostat
1.  Open  the  battery  door  and  detach  the  new  thermostat 
cover from the base.
2.  With the base flush against the wall, mark mounting hole 
locations on wall.
3.  Move base out of the way and drill mounting holes.
4.  Push wires through wire opening.
5.  Position the base on the wall again and screw the mounting 
screws into the wall anchors.
6.  Connect each wire coming from the wall to its corresponding 
terminal as shown in Fig. 2 thru 4 on page 7.
NOTE
Wires  will  not  be  connected  to  all  terminals  of  the  terminal 
block.
Installation 
Mounting
Hole
Mounting
Hole
Opening
for wires
Gas/Elec
Switch
Battery
Door
O/B
Switch
Figure 1. Thermostat Base
Set Switches
Gas / Elec Switch
If your system is a heat pump, the GAS/ELEC Switch must 
be set to ELEC (see Fig. 1) If your system is a single stage, 
the switch must be set to GAS. The switch setting must agree 
with the system configuration selected in the configuration 
menu.
O/B Terminal Switch Selection
The O/B switch on this thermostat is factory set to the “O” 
position. This will accommodate the majority of heat pump 
applications, which require the changeover relay to be 
energized in COOL. If the thermostat you are replacing or the 
heat pump being installed with this thermostat requires a “B” 
terminal, to energize the changeover relay in HEAT, the O/B 
switch must be moved to the “B” position.
Check Thermostat Operation
Heating System
1.  Move SYSTEM switch to 
HEAT position. If the heating 
system has a standing pilot, be sure to light it.
2.  Press 
 to adjust thermostat setting to 1° above room 
temperature. The heating system should begin to operate.  
3.  Press 
 to adjust temperature setting below room 
temperature. The heating system should stop operating.
Fan Operation
If your system 
does not have a G terminal connection, skip to 
Heating System.
1.  Move SYSTEM switch to OFF position. 
2.  Move fan switch to 
ON position. The blower should begin 
to operate.
3.  Move fan switch to 
AUTO position. The blower should stop 
immediately.
Cooling System
1.  Move SYSTEM switch to 
COOL position.
2.  Press 
 to adjust thermostat setting below room 
temperature. The blower should come on immediately on 
high speed, followed by cold air circulation. However, if the 
setpoint temperature is flashing, the compressor lockout 
feature is operating (see Configuration menu, item 5).
3.  Press 
 to adjust temperature setting above room 
temperature. The cooling system should stop operating.
Wire Terminal Block
R
C
O/B
W
Y
G
Press down
Insert
Wire