SECTION XIII:  INSTALLATION FOR POTABLE WATER AND SPACE HEATING 
 
THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: 
GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING 
 
1.  All piping components connected to this water heater for space-heating applications must be suitable for use with 
potable water.  In Massachusetts, space heating piping must not exceed 50 feet. 
2.  Toxic chemicals, such as those used for boiler treatment, must not be introduced into potable water used for space 
heating. 
3.  This water heater must not be connected to an existing heating system or component(s) previously used with a non-
potable water   heating appliance. 
4.  When the system requires water for space heating at temperatures higher than required for other uses, such as an 
ASSE approved mixing valve must be installed to temper the water for those uses in order to reduce the scald hazard 
potential. 
 
Please refer to the illustrations below and on the following pages for suggested piping arrangements. 
 
 
 
Suggested Piping Arrangement For Side Connections      Suggested Piping Arrangement For Top and Side Connections 
 
 
 
 
Suggested Piping Arrangement For Top Connections