American Water Heater 319339-000 Fascicule

Page de 2
Order Entry and Sales
500 Princeton Road (FEDEX, UPS)
Johnson City, TN 37601-2030
P.O. Box 4808 (Mailing)
Johnson City, TN   37602-4808
(800) 937-1037
FAX (800) 581-7224
No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters. 
Distributed By:
Warranty and Service
500 Princeton Road (FEDEX, UPS)
Johnson City, TN   37601-2030
 P.O. Box 1597 (Mailing)
Johnson City, TN   37605-1597
(800) 456-9805
FAX (800) 999-5210
Residential Gas 
High Efficiency Power Vent  
Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______ -year tank 
warranty and a ______ -year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of ______ gallons and shall have a rated 
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA4.1 standard.  
Heaters shall meet or exceed the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 
1992.  The interior of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F,  forming a corrosion-resistant lining; polymer linings 
are not acceptable.  Each tank shall be furnished with an internal powered anode for cathodic protection.  The unit must be equipped with a combination gas control 
thermostat and non-reset type ECO.  A corrosion-resistant drain valve shall be provided on the front of each unit.  The tank shall be totally encased in a steel jacket, painted 
and insulated with a non-CFC foam to reduce standby heat loss.  The tank must be design certified for 300 PSI test pressure and 150 working pressure.
Residential Gas Water Heater Specification
NRGSS01110
Inlet and outlet connections: 3/4” male
Circulation loop connections: 3/4” female
90% THERMAL EFFICIENCY POWER VENT
CODES AND STANDARDS
•  Design-certified by UL (Underwriters Laboratories) according to ANSI Z21.10.3 - CSA 4.3 Standards
•  Meets or exceeds the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition ASHRAE/IESNA 90.1
MODEL
NUMBER
BTU
INPUT
PER 
HOUR
GALLONS
OR
LITRES
FIRST HOUR 
DELIVERY 
GALLONS
OR
LITRES
RECOVERY
GALLONS
OR
LITRES
90°F/50°C RISE
DIMENSIONS
INCHES/CENTIMETERS
SHIPPING 
WEIGHT
LBS/KG
A
B
C
D
E
F
G
H
J
K
VG6250T76NV
76,000
50
127
92
70-5/8 68-1/4
52
21
9-1/8
12
22
8
15-3/4
27
210
189
481
92
179
173
132
53
23
30
56
20
40
68
95
(B)
* INSTALL IN ACCORDANCE WITH LOCAL CODES
TOP VIEW
ANODE
(J)
(H)
(K)
HOT
COLD
(A)
(C)
(G)
(F)
(D)
(E)
DIAMETER
SIDE INLET
THERMOSTAT
DRAIN
VALVE
T & P VALVE
SIDE OUTLET
OUTLET
(L)
(L)
INLET
FRONT VIEW
NRGSS01110 Res Gas Spec.indd   2
7/8/10   11:08 AM