Empire Comfort Systems DVP48FP9 Manuel D’Utilisation

Page de 52
Page 41
17375-6-0705
FIRST USE OF TRANSMITTER
Status
Action
Begin communication between transmitter and receiver/valve.
Move LOCAL/REMOTE Switch to LOCAL position for at least 
two seconds; then move switch to the REMOTE position.
Transmit unique code.
Press Fan or Flame key within 30 seconds.
Confirm recognition between transmitter and receiver/valve.
Observe LED turns on for one second.
Chose Remote or Local operation.
Move LOCAL/REMOTE switch to LOCAL or leave in REMOTE.
Operation in the Remote Position
AUTO Mode
 
With the control in the AUTO mode, the flame in the main burner will turn on, off, or change height based on the heat needed to maintain the set 
temperature.
Status
Action
Set to AUTO.
Press MODE button until mode is AUTO.
Change set temperature.
Press UP or DOWN key to change set temperature.
Flame.
Automatically changes.
Fan.
Automatically changes.
To Set Delay Timer.
Press TIME key followed by either an UP or DOWN arrow key.
CAUTION 
Properly Damage Hazard. 
Excessive heat can cause property damage. 
In AUTO mode, the main burner will cycle indefinitely to maintain the set temperature. Keep the transmitter in a heated living space to make sure 
that the main burner is not on continuously.
On Mode 
When the control is in the ON mode, the flame and fan levels and the delay timer are changed with the UP and DOWN arrow keys.
Status
Action
Set to ON.
Press MODE button until mode is ON.
Flame.
Press FLAME button and press UP or DOWN arrow key to change 
flame height.
Fan.
Press FAN button and press UP or DOWN arrow key to change fan 
speed.
Delay Time.
Press DELAY TIMER button and press UP or DOWN key to 
change timer.
OFF Mode 
The flame in the main burner will turn off and the room 
temperature will be displayed in the remote window.
Press MODE until mode is OFF.
Operation in the LOCAL Mode. 
NOTE: Remote/Local switch on the receiver/valve must be in the LOCAL position.
FAN 
Flame height and fan speed both go to the highest position.
In LOCAL mode, to turn flame on/off, rotate manual knob from 
ON to PILOT position.
Other Functions:
Change between Fahrenheit and Celsius temperature units.
Press UP and DOWN arrow keys at the same time and hold for at 
least three seconds.
Fan Override during AUTO Mode.
Press FAN button, and press UP or DOWN arrow key to change 
the fan speed.
Disable thermostat function in the AUTO Mode
Press the TIME, DOWN and FLAME arrow keys at the same time 
and hold for at least three seconds.
RF TRANSMITTER FUNCTIONS